Comparison of a unipolar defibrillation system with a dual lead system using an enlarged defibrillation anode.
MedLine Citation:
PMID:  8994947     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The unipolar system for transvenous defibrillation, consisting of a single right ventricular lead as the cathode and the device shell as anode, has been shown to combine low defibrillation thresholds (DFTs) and simple implantation techniques. We compared the defibrillation efficacy of this system with the defibrillation efficacy of a dual lead system with a 12-cm long defibrillation anode placed in the left subclavian vein. The data of 38 consecutive patients were retrospectively analyzed. The implantation of an active can system was attempted in 20 patients (group 1), and of the dual lead system in 18 patients (group 2). Both groups had comparable demographic data, cardiac disease, ventricular function, or clinical arrhythmia. The criterion for successful implantation was a DFT of < or = 24 J. This criterion was met in all 18 patients of group 2. The active can system could not be inserted in 3 of the 20 group 1 patients because of a DFT > 24 J. In these patients, the implantation of one (n = 2) or two (n = 1) additional transvenous leads was necessary to achieve a DFT < or = 24 J. The DFTs of the 17 successfully implanted group 1 patients were not significantly different from the 18 patients in group 2 (12.3 +/- 5.7 J vs 10.8 +/- 4.8 J). The defibrillation impedance was similar in both groups (50.1 +/- 6.1 omega vs 48.9 +/- 5.2 omega). In group 1, both operation duration (66.8 +/- 17 min vs 80.8 +/- 11 min; P < 0.05) and fluoroscopy time (3.3 +/- 2.1 min vs 5.7 +/- 2.9 min; P < 0.05) were significantly shorter. Thus, the active can system allows reliable transvenous defibrillation and a marked reduction of operation duration and fluoroscopy time. The dual lead system, with an increased surface area defibrillation anode, seems to be a promising alternative for active can failures.
Authors:
S Mattke; M Fiek; A Markewitz; D Müller; E Hoffmann; M Schmöckel; G Steinbeck
Related Documents :
3990327 - Right ventricular outflow tract reconstruction with a bovine pericardial monocusp patch...
21976907 - Treatment of lipoma by injection lipolysis.
9462417 - Surgical repair for atrial septal defect in patients over 70 years of age.
20078707 - Surgical treatment of postinfarction left ventricular free wall rupture.
9042177 - Ultrasound-guided compression for the treatment of iatrogenic femoral pseudoaneurysms.
20010547 - The miller banding procedure is an effective method for treating dialysis-associated st...
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  19     ISSN:  0147-8389     ISO Abbreviation:  Pacing Clin Electrophysiol     Publication Date:  1996 Dec 
Date Detail:
Created Date:  1997-04-04     Completed Date:  1997-04-04     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  2083-8     Citation Subset:  IM    
Affiliation:
Ludwig-Maximilians-Universität München, Medizinische Klinik I, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Defibrillators, Implantable*
Equipment Design
Female
Follow-Up Studies
Humans
Male
Middle Aged
Retrospective Studies

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Initial single-center experience with an advanced third-generation investigational defibrillator.
Next Document:  Transtelephone monitoring for pacemaker follow-up 1981-1994.