Comparison of two flow generators with a noninvasive ventilator to deliver continuous positive airway pressure: a test lung study.
MedLine Citation:
PMID:  16222519     Owner:  NLM     Status:  MEDLINE    
OBJECTIVE: To compare the performance of two continuous flow generators with a ventilator designed for noninvasive positive pressure ventilation (NPPV) to deliver continuous positive airway pressure (CPAP). The performance of flow generators using different oxygen pressure supplies was also compared. DESIGN AND SETTING: Experimental study using a mechanical lung model in a university research laboratory. MEASUREMENTS: Two flow generators supplied at 100, 200, and 300 kPa and an NPPV ventilator were compared at CPAP of 5, 10, and 15 cmH2O in: (a) area under the adjusted CPAP level during inspiration, (b) capacity to attain the preset CPAP, and (c) tidal volume. RESULTS: The NPPV ventilator attained the preset CPAP better than flow generators, but its area under adjusted CPAP was similar to or higher than that of flow generators when these were adjusted to their better pressure supply. Both flow generators had better performance with an output flow around 100 l/min, which was achieved at 100 kPa with one flow generator and 300 with the other. Flow generators and the NPPV ventilator generated similar tidal volumes. CONCLUSIONS: Flow generators performance showed large variations among different devices and oxygen pressure supplies. Adjusted to their better pressure supply, flow generators had a similar or better capacity to maintain the CPAP level, but the NPPV ventilator was more reliable to attain the preset CPAP. Flow generators could be an alternative to provide CPAP in low-income areas, usually with scarce medical equipment availability.
Carolina Fu; Pedro Caruso; Jeanette Janaina Jaber Lucatto; Guilherme Pinto de Paula Schettino; Rogério de Souza; Carlos Roberto Ribeiro Carvalho
Related Documents :
9920529 - The micro-plethysmograph: a new device to measure small volume displacements by isolate...
2496089 - Influence of respiratory drive on upper airway resistance in normal men.
6538129 - Overestimation of inspiratory upper airway resistance.
362359 - Effects of continuous positive airway pressure after oleic acid-induced lung injury in ...
8181299 - Timing of pressure release affects power of breathing and minute ventilation during air...
3745069 - Effects of aerosol histamine and carbachol on central and peripheral airflow resistance...
11786109 - Relationship between volume status and blood pressure during chronic hemodialysis.
9663919 - Angiotensin converting enzyme inhibition and calcium antagonism attenuate streptozotoci...
2811779 - Epidural meperidine for control of autonomic hyperreflexia in a quadriplegic undergoing...
Publication Detail:
Type:  Comparative Study; Journal Article     Date:  2005-10-13
Journal Detail:
Title:  Intensive care medicine     Volume:  31     ISSN:  0342-4642     ISO Abbreviation:  Intensive Care Med     Publication Date:  2005 Nov 
Date Detail:
Created Date:  2005-11-11     Completed Date:  2006-01-31     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  7704851     Medline TA:  Intensive Care Med     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1587-91     Citation Subset:  IM    
Physiotherapy, Phonology and Occupational Therapy Department, Medical School, University of São Paulo, São Paulo, Brazil.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Artificial Organs
Continuous Positive Airway Pressure / instrumentation*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Prospective and controlled studies of the actions of insulin and catecholamine in fat cells of obese...
Next Document:  Partial duplication of the scapula.