Document Detail


Comparison of therapy detection times between implantable cardioverter defibrillators with standard dual- and single-chamber pacing.
MedLine Citation:
PMID:  10525248     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Previous implantable cardioverter defibrillators (ICDs) required patients in need of dual-chamber (DDD) pacing for improved hemodynamic status to undergo implantation of separate devices to treat bradycardia and/or ventricular arrhythmias. An investigation was conducted to verify the performance of a new ICD that combines both therapies.Sixty-nine patients at 17 European and Canadian centers were implanted with VENTAK AV models 1810/1815, ICD's that includes DDD pacing and algorithms designed to differentiate between atrial and ventricular arrhythmias. 36 of the cohort were compared to 32 patients tested at six centers with an external test device (VENTAK MINI). In both cohorts detection times were calculated for ventricular fibrillation (VF) induced at implant. The mean detection times (DT) from the VENTAK AV device were compared to the DT from the VENTAK MINI device. Patient characteristics of the VENTAK AV and the VENTAK MINI control groups were similar. Mean VF detection time (+/-SD) with the VENTAK AV device was 2.21 +/- 0.54 seconds, as compared with 1.87 +/- 0.62 seconds with the VENTAK MINI (p < 0.01), indicating that the difference in means did not exceed one second. The VENTAK AV system function did not demonstrate interaction with the pacemaker function, as indicated by the clinical significance with the detection times of the study device. The difference in detection times between cohorts did not statistically exceed one second. Appropriate detection of the new ICD was not compromised by the addition of the dual-chamber pacing therapy.
Authors:
A Capucci; G Q Villani; F Groppi; D Aschieri; M Hull; M Kuehl
Related Documents :
21367208 - 227 the effects of sexed semen on embryonic development to the blastocyst stage.
22875198 - Development of a decellularised dermis.
17606938 - Use of implantable cardioverter defibrillators in canadian and us survivors of out-of-h...
22814558 - Clinical and radiographic outcome of dental implants supporting fixed prostheses: the r...
8175188 - Effect of sulfur dioxide on mucociliary activity and ciliary beat frequency in guinea p...
6672468 - A technique for measuring the perception of added resistive loads during nasal breathing.
Publication Detail:
Type:  Clinical Trial; Comparative Study; Controlled Clinical Trial; Journal Article; Multicenter Study    
Journal Detail:
Title:  Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing     Volume:  3     ISSN:  1383-875X     ISO Abbreviation:  J Interv Card Electrophysiol     Publication Date:  1999 Dec 
Date Detail:
Created Date:  1999-12-23     Completed Date:  1999-12-23     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9708966     Medline TA:  J Interv Card Electrophysiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  329-33     Citation Subset:  IM    
Affiliation:
Ospedale Civile Piacenza, Italy. a.capucci@auslpc.agonet.it
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Adult
Aged
Child
Cohort Studies
Defibrillators, Implantable*
Electric Countershock*
Equipment Design
Female
Humans
Male
Middle Aged
Tachycardia, Ventricular / therapy*
Time Factors
Ventricular Fibrillation / therapy*