Document Detail


Comparison of real and simulated hearing impairment in subjects with unilateral and bilateral cochlear hearing loss.
MedLine Citation:
PMID:  9307819     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Simulations of hearing impairment were presented to the normal ears of subjects with moderate to severe unilateral cochlear hearing loss. The intelligibility of speech in quiet and in background sounds was compared with that obtained for the impaired ears using unprocessed stimuli. The results of loudness matches between the two ears were used to tailor a simulation of threshold elevation combined with loudness recruitment individually for each subject. This was assessed either alone, or in combination with a simulation of reduced frequency selectivity, performed by spectral smearing. Finally, we included a simulation of 'dead' regions in the cochlea, where there are assumed to be no functioning inner hair cells and/or neurones, by band-stop filtering over the frequency range corresponding to the dead region. Performance for the impaired ears was markedly worse than for the normal ears using the simulation of threshold elevation and loudness recruitment. The addition of the simulation of reduced frequency selectivity caused performance to worsen, but it remained above that for the impaired ears. The additional simulation of a dead region had little effect, except for one subject, for whom it produced performance comparable to that for the impaired ear in quiet but not when background sounds were present. It is suggested that the relatively poor results for the impaired ears may be caused partly by a form of 'neglect' which is specific to subjects with unilateral or asymmetric loss. This idea was supported by results obtained using bilaterally hearing-impaired subjects, which were markedly better than for the impaired ears of the unilaterally hearing-impaired subjects, and comparable to those for the normal ears listening to the combined simulation of threshold elevation, loudness recruitment and reduced frequency selectivity.
Authors:
B C Moore; D A Vickers; B R Glasberg; T Baer
Related Documents :
11504359 - Effects of peak levels and number of impulses to hearing among forge hammering workers.
7209369 - The effects of impulsive noise upon human hearing sensitivity (8 to 20 khz).
738989 - Hearing threshold for a decaying oscillatory waveform.
17952509 - Age-related hearing loss in c57bl/6j mice has both frequency-specific and non-frequency...
20330619 - Unique challenges for hearing protection in military noise environments.
20370049 - Psychophysical and electrophysiological aerial audiograms of a steller sea lion (eumeto...
25236879 - Photo-chemopropulsion - light-stimulated movement of microdroplets.
17013889 - Muscle activation assessment: effects of method, stimulus number, and joint angle.
1624039 - Light and the immature visual system.
Publication Detail:
Type:  Comparative Study; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  British journal of audiology     Volume:  31     ISSN:  0300-5364     ISO Abbreviation:  Br J Audiol     Publication Date:  1997 Aug 
Date Detail:
Created Date:  1997-12-29     Completed Date:  1997-12-29     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0357321     Medline TA:  Br J Audiol     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  227-45     Citation Subset:  IM    
Affiliation:
Department of Experimental Psychology, University of Cambridge, England.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Audiometry, Pure-Tone
Auditory Threshold
Cochlea / physiopathology*
Diagnosis, Differential
Hearing Loss / diagnosis*
Hearing Loss, Sensorineural / diagnosis*,  physiopathology*
Humans
Hyperacusis
Middle Aged
Severity of Illness Index
Speech Discrimination Tests
Speech Perception

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The future of cochlear implants.
Next Document:  Integrity testing of cochlear implants in the awake child.