Comparison of noninvasive blood pressure measurements in patients with atrial fibrillation.
MedLine Citation:
PMID:  18953216     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND AND RESEARCH OBJECTIVE: Limited research is available on the accuracy of automatic blood pressure (BP) measurement devices in patients with irregular rhythms. The purpose of this study was to examine the agreement between different methods for noninvasive BP measurement in patients with atrial fibrillation. SUBJECTS AND METHODS: In a convenience sample of hospitalized patients with atrial fibrillation, a method-comparison study design was used to examine the agreement between 2 noninvasive devices for BP measurement (manual, automated). Blood pressure was obtained sequentially, with each device following manufacturer's directions and American Heart Association guidelines for BP determination and with BP order determined by random assignment. Heart rate and rhythm were determined from a continuous electrocardiographic monitoring. Heart rate was also recorded from the automated BP device. Differences and limits of agreement between the automated and reference standard (manual) BP devices were calculated and graphed according to the Bland-Altman method. Student t test was used to test differences in BP obtained with the 2 devices, as well as heart rate differences between the electrocardiographic monitor and automated BP device. The level of significance for all tests was set at 0.05. RESULTS: 53 participants were observed. Bland-Altman analysis found a bias plus/minus precision of -0.91 +/- 11.4 mm Hg for systolic BP and 3.3 +/- 6.9 mm Hg for diastolic BP. A significant difference was found for the diastolic BP obtained with the automated device and with that of the manual device (t52 = 3.51, P = .0009) and for heart rate differences between the automated BP device and the cardiac monitor (t52 = 2.4, P = .0217). CONCLUSION: This study confirms that in the presence of irregular cardiac rhythms, diastolic BP and heart rate cannot reliably be measured with an automated BP device.
Authors:
Zoe M Anastas; Elnora Jimerson; Salomeja Garolis
Related Documents :
10423686 - Diurnal variations of blood pressure in dogs.
11866236 - Reproducibility and validity of ambulatory blood pressure monitoring in children.
11055476 - Testosterone increases blood pressure and cardiovascular and renal pathology in spontan...
8273876 - The australian incident monitoring study. blood pressure monitoring--applications and l...
16236976 - Physiologic evaluation of different levels of assistance during noninvasive ventilation...
4087696 - Norepinephrine-related mechanism in hypertension accompanying renal failure.
Publication Detail:
Type:  Comparative Study; Journal Article; Validation Studies    
Journal Detail:
Title:  The Journal of cardiovascular nursing     Volume:  23     ISSN:  1550-5049     ISO Abbreviation:  J Cardiovasc Nurs     Publication Date:    2008 Nov-Dec
Date Detail:
Created Date:  2008-10-27     Completed Date:  2008-12-31     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8703516     Medline TA:  J Cardiovasc Nurs     Country:  United States    
Other Details:
Languages:  eng     Pagination:  519-24; quiz 525-6     Citation Subset:  IM; N    
Affiliation:
Providence Portland Medical Center, Portland, OR 97213, USA. zoe.anastas@providence.org
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged, 80 and over
Atrial Fibrillation / complications*,  diagnosis,  physiopathology
Automation
Bias (Epidemiology)
Blood Pressure Determination / instrumentation,  methods*,  nursing,  standards
Clinical Nursing Research
Confounding Factors (Epidemiology)
Diastole
Electrocardiography
Female
Heart Rate
Humans
Male
Monitoring, Physiologic / methods,  standards
Nursing Assessment
Regression Analysis
Stroke Volume
Systole

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Health-risk appraisal with or without disease management for worksite cardiovascular risk reduction.
Next Document:  Exploring uncertainty and psychosocial adjustment after cardioverter defibrillator implantation.