Comparison of in vitro valve pressure drop results from different investigators.
MedLine Citation:
PMID:  6727725     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Steady-state pressure-drop vs flow-rate measurements on prosthetic valves have been shown to correlate well with mean cyclic pressure drops vs RMS flow rate during systolic ejection from pulsatile flow data. The use of steady-state data is therefore validated as a means of assessing performance characteristics. Pressure-drop results reported in the literature were compared for valves of the same size and manufacture. Significant differences were noted, which are attributed to: (a) different geometries in the region of the valves, (b) different approach flow conditions, (c) different placement of pressure measurement taps, and (d) different methods of pressure measurement. Differences in pressure drop were observed to vary by as much as a factor of five among different investigators. The exponent n in the relation delta p infinity Q" was also observed to vary, depending on the above factors. The reasons for and some quantitative calculations on the observed differences are presented here.
Authors:
W M Swanson
Related Documents :
2304885 - Significance of the doppler-derived gradient across a residual aortic coarctation.
24627995 - S-nitrosoglutathione improves haemodynamics in early-onset pre-eclampsia.
286905 - Hypertension in valvar aortic stenosis.
824315 - An animal model for experimental echocardiographic studies.
21778045 - Ultra-rapid flow-through polymerase chain reaction microfluidics using vapor pressure.
24479265 - Intraocular/intracranial pressure mismatch hypothesis for visual impairment syndrome in...
Publication Detail:
Type:  Comparative Study; Journal Article; Research Support, U.S. Gov't, P.H.S.    
Journal Detail:
Title:  Medical instrumentation     Volume:  18     ISSN:  0090-6689     ISO Abbreviation:  Med Instrum     Publication Date:    1984 Mar-Apr
Date Detail:
Created Date:  1984-07-11     Completed Date:  1984-07-11     Revised Date:  2007-11-14    
Medline Journal Info:
Nlm Unique ID:  0361136     Medline TA:  Med Instrum     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  115-7     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aortic Valve
Bioprosthesis / standards*
Heart Valve Prosthesis / standards*
Mitral Valve
Rheology
Grant Support
ID/Acronym/Agency:
HL-13803/HL/NHLBI NIH HHS

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  An on-line method for evaluation of the in vitro pulsatile pressure drop and regurgitative character...
Next Document:  A simple-time-series approach for evaluating an ocular plethysmograph.