Document Detail


Comparison in the interface pressure under self-adherent and non-self-adherent bandages during standing and exercise.
MedLine Citation:
PMID:  9859744     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Self-adherent bandages are useful to prevent the bandage from becoming loose. However, the material binds tightly to itself to form a tight band, which may result in changes in interface pressure under the bandages during changes in posture and exercise, because the pressure depends on the elasticity of the bandages. The aim of this study was to compare the interface pressures under self-adherent and non-self adherent bandages while standing and during exercise.
PATIENTS AND METHODS: In 20 normal volunteers the pressure was determined at the posteromedial area of the midcalf during lying, standing, tip-toe exercise and walking, using an Air Pack Type Analyzer. We examined two kinds of bandages with a maximal tension of 70%, self-adherent and non-self-adherent bandages.
RESULTS: There was no significant increase in pressure observed during standing in comparison with pressure in the supine position immediately after application. A significant increase in pressure under both bandages was observed during tip-toe exercise and walking. However, there was no significant difference in pressure during standing or exercise between self-adherent and non-self-adherent bandages. Furthermore, there was no significant pressure difference between muscle contraction and relaxation between the two bandages.
CONCLUSION: Self-adherent bandages can maintain their own elasticity, even when the material binds tightly to itself.
Authors:
M Hirai
Related Documents :
1192674 - Tissue pressure measurements as a determinant for the need of fasciotomy.
7502994 - Exposures while applying commercial disinfectants.
12188074 - Grip strength: effect of hand dominance.
11677964 - The influence of omentectomy on the inflammatory phase of anastomotic healing.
19960134 - Successful treatment of hypertension accounts for improvements in markers of diastolic ...
7742964 - Failure of the community-based vita-stat automated blood pressure device to accurately ...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  VASA. Zeitschrift für Gefässkrankheiten     Volume:  27     ISSN:  0301-1526     ISO Abbreviation:  VASA     Publication Date:  1998 Nov 
Date Detail:
Created Date:  1999-03-03     Completed Date:  1999-03-03     Revised Date:  2012-10-19    
Medline Journal Info:
Nlm Unique ID:  0317051     Medline TA:  Vasa     Country:  SWITZERLAND    
Other Details:
Languages:  eng     Pagination:  233-5     Citation Subset:  IM    
Affiliation:
Department of Surgery, Aichi Prefectural College of Nursing, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Bandages*
Elasticity
Exercise / physiology*
Female
Humans
Leg / blood supply*
Muscle Contraction / physiology
Posture / physiology*
Pressure
Venous Insufficiency / physiopathology

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The hydrostatic measurement of systolic toe blood pressure: a preliminary validation of the method.
Next Document:  Knitted double-velour Dacron prostheses in aortobifemoral position--long-term performance of differe...