Document Detail


Comparison of hearing-aid gain using functional, coupler, and probe-tube measurements.
MedLine Citation:
PMID:  3724114     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Measurements of functional gain were compared first to coupler gain for 57 subjects using one of three hearing aid-earmold combinations and second to probe-tube gain for 12 subjects using in-the-ear hearing aids. The average difference between functional and coupler gain plotted as a function of frequency yielded results that were similar to previous reports, with the greatest effects occurring at 3000 and 4000 Hz. Significant differences were seen among hearing aid-earmold combinations at 3000, 4000, and 6000 Hz. Standard deviations for measurements between 750 and 2000 Hz were less than 5 dB and could be explained by variability of functional gain measures associated with test-retest variability of thresholds measured in a sound field. Below 750 Hz and above 2000 Hz, standard deviations exceeded 5 dB. The greater variability may be explained by differences in earmold venting, acoustic characteristics of the ear canal, and stimuli used to measure functional and coupler gain. Neither room nor hearing-aid noise appeared to affect the results significantly. When functional gain was compared to insertion gain measured with a probe-tube system, the average difference across frequencies was less than 1 dB. The variability of the differences at all frequencies, with the exception of 6000 Hz, was within the range reported for functional gain measurements. It was concluded that functional gain can be accurately estimated using probe-tube measurements.
Authors:
D Mason; G R Popelka
Related Documents :
6612214 - Noise-induced hearing loss in shipyard workers with unilateral conductive hearing loss.
20330484 - Auditory models of suprathreshold distortion in persons with sensorineural hearing loss.
3558964 - The effect of varying the slope of the amplitude-frequency response on the masked speec...
15558994 - Hearing thresholds during gz acceleration with masking noise.
8749124 - A quantitative analysis of head-shaking nystagmus of peripheral vestibular origin.
4416354 - The measurement of response force during a lever-press shock-escape procedure in rats.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Journal of speech and hearing research     Volume:  29     ISSN:  0022-4685     ISO Abbreviation:  J Speech Hear Res     Publication Date:  1986 Jun 
Date Detail:
Created Date:  1986-08-06     Completed Date:  1986-08-06     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0376336     Medline TA:  J Speech Hear Res     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  218-26     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Audiometry, Pure-Tone
Auditory Threshold
Hearing Aids / standards*
Hearing Loss, Bilateral / therapy
Hearing Loss, Sensorineural / therapy*
Humans

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Direct language instruction and interactive language instruction with language delayed preschool chi...
Next Document:  Marking word boundaries to improve the intelligibility of the speech of the deaf.