Comparison of frequency difference reconstruction algorithms for the detection of acute stroke using EIT in a realistic head-shaped tank.
MedLine Citation:
PMID:  22531059     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Imaging of acute stroke might be possible using multi-frequency electrical impedance tomography (MFEIT) but requires absolute or frequency difference imaging. Simple linear frequency difference reconstruction has been shown to be ineffective in imaging with a frequency-dependant background conductivity; this has been overcome with a weighted frequency difference approach with correction for the background but this has only been validated for a cylindrical and hemispherical tank. The feasibility of MFEIT for imaging of acute stroke in a realistic head geometry was examined by imaging a potato perturbation against a saline background and a carrot-saline frequency-dependant background conductivity, in a head-shaped tank with the UCLH Mk2.5 MFEIT system. Reconstruction was performed with time difference (TD), frequency difference (FD), FD adjacent (FDA), weighted FD (WFD) and weighted FDA (WFDA) linear algorithms. The perturbation in reconstructed images corresponded to the true position to <9.5% of image diameter with an image SNR of >5.4 for all algorithms in saline but only for TD, WFDA and WFD in the carrot-saline background. No reliable imaging was possible with FD and FDA. This indicates that the WFD approach is also effective for a realistic head geometry and supports its use for human imaging in the future.
Authors:
B Packham; H Koo; A Romsauerova; S Ahn; A McEwan; S C Jun; D S Holder
Related Documents :
20709619 - Cytokinesis through biochemical-mechanical feedback loops.
22465779 - Value of susceptibility-weighted imaging in acute hemorrhagic leukoencephalitis.
6881069 - Uses and selection of equipment for engineering control monitoring.
18965379 - Automated measurement of dye coverage in photographic negatives by flow-injection analy...
18252399 - Decentralized control of discrete event systems with specializations to local control a...
18190129 - Max mathews' magical music machines.
10719699 - Observation study of electronic portal images for off-line verification.
22398009 - Atrial isomerism: a pictorial review.
21606029 - Real-time affine global motion estimation using phase correlation and its application f...
Publication Detail:
Type:  Journal Article     Date:  2012-04-24
Journal Detail:
Title:  Physiological measurement     Volume:  33     ISSN:  1361-6579     ISO Abbreviation:  Physiol Meas     Publication Date:  2012 May 
Date Detail:
Created Date:  2012-04-25     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9306921     Medline TA:  Physiol Meas     Country:  England    
Other Details:
Languages:  eng     Pagination:  767-86     Citation Subset:  IM    
Affiliation:
Department of Medical Physics and Bioengineering, UCL, London, UK.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Optimization of reaction conditions for enzymatic synthesis of palm fatty hydrazides using response ...
Next Document:  Dosimetric consequences of translational and rotational errors in frame-less image-guided radiosurge...