Document Detail


Comparison of five bilevel pressure ventilators in patients with chronic ventilatory failure: a physiologic study.
MedLine Citation:
PMID:  12475854     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: To compare patient-ventilator interaction and comfort in patients with chronic ventilatory failure (CVF) who are undergoing noninvasive positive-pressure ventilation with five different commercial bilevel pressure home ventilators. Also, we wanted to evaluate the short-term effects of the five ventilators on physiologic variables, namely, breathing patterns and inspiratory muscles. DESIGN: Randomized, controlled physiologic study. SETTING: Pulmonary division of a rehabilitation institution. PATIENTS: Twenty-eight patients with CVF due to COPD (17 patients) and restrictive chest wall diseases (11 patients). MEASUREMENTS: Sensation of comfort, breathing patterns and minute ventilation (E), respiratory muscles and mechanics, and patient-ventilator interaction during both unassisted and assisted ventilation with the five ventilators applied randomly. RESULTS: The five ventilators showed different flow and pressure waveforms. The level of comfort was somehow different among the studied ventilators. When compared to unassisted ventilation, all ventilators induced a significant increase in E (p < 0.01) without any significant difference among ventilators. Use of the five ventilators resulted in significant differences in peak airway opening pressure (Pao,peak) but not in mean airway opening pressure computed over a period of 1 min (PTPao,min), and in a duty cycle. Ineffective efforts (IEs) were similar among the studied ventilators. In comparison with unassisted ventilation, all ventilators induced significant reductions in inspiratory muscle effort (p < 0.001). No significant relationship was found between level of comfort and PTPao,min, Pao,peak, or the number of IEs. CONCLUSIONS: In stable, awake patients with CVF, all of the studied ventilators were well-tolerated, although with a great intersubject variability in comfort, and performed well in terms of improvement in E and inspiratory muscle unloading, thus fulfilling the aims of mechanical ventilation. This effect was obtained with similar levels of PTPao,min, despite the fact that Pao,peak was different among some ventilators. The number of IEs was similar among the studied ventilators.
Authors:
Michele Vitacca; Luca Barbano; Silvestro D'Anna; Roberto Porta; Luca Bianchi; Nicolino Ambrosino
Related Documents :
6344894 - High frequency positive pressure ventilation (hfppv) in a newborn infant with ruptured ...
7027724 - Incentive spirometry. prevention of pulmonary complications after abdominal surgery.
8856804 - Comparison of total resistive work of breathing in two generations of ventilators in an...
153624 - Steady-state gas exchange in normothermic, anesthetized, liquid-ventilated dogs.
12701234 - Is elbow breadth a measure of frame size in non-caucasian populations? a study in low- ...
22520644 - Effect of letrozole on uterine tonus and contractility: a randomized controlled trial.
Publication Detail:
Type:  Clinical Trial; Comparative Study; Journal Article; Randomized Controlled Trial    
Journal Detail:
Title:  Chest     Volume:  122     ISSN:  0012-3692     ISO Abbreviation:  Chest     Publication Date:  2002 Dec 
Date Detail:
Created Date:  2002-12-11     Completed Date:  2003-01-29     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0231335     Medline TA:  Chest     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2105-14     Citation Subset:  AIM; IM    
Affiliation:
Pulmonary Division, Scientific Institute, Fondazione Salvatore Maugeri IRCCS, I-25064 Gussago (BS), Italy.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Chronic Disease
Female
Humans
Male
Middle Aged
Positive-Pressure Respiration / instrumentation*
Pulmonary Disease, Chronic Obstructive / complications
Respiratory Insufficiency / therapy*
Thoracic Diseases / complications
Ventilators, Mechanical*
Comments/Corrections
Comment In:
Chest. 2002 Dec;122(6):1881-3   [PMID:  12475818 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Effects of inspiratory flow waveforms on lung mechanics, gas exchange, and respiratory metabolism in...
Next Document:  Epidemiology and outcomes of ventilator-associated pneumonia in a large US database.