Document Detail


Comparison of the effects of pulsatile cardiopulmonary bypass, non-pulsatile cardiopulmonary bypass and off-pump coronary artery bypass grafting on the inflammatory response and s100beta protein.
MedLine Citation:
PMID:  22002967     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: We aimed to investigate the effects of off-pump coronary artery bypass grafting, pulsatile cardiopulmonary bypass, and non-pulsatile cardiopulmonary bypass techniques on the inflammatory response and the central nervous system in the current study. METHODS: A total of 32 patients who were scheduled for elective coronary artery bypass graft surgery were included in the study. The patients were allocated into three different groups according to the perfusion techniques used during the cardiopulmonary bypass procedure as follows: off-pump coronary artery bypass grafting group (n=10); pulsatile cardiopulmonary bypass group (n=11); and non-pulsatile cardiopulmonary bypass group (n=11). Serum interleukin-6, interleukin-8, tumor necrosis factor-alpha and S-100beta levels were measured preoperatively, and at 0, 6, and 24 hours postoperatively. RESULTS: The postoperative increase in the levels of interleukin-6 and interleukin-8 was significantly lower in the off-pump group compared to the other two groups (p<0.05), while there was no significant difference in tumor necrosis factor-alpha levels between the groups. Postoperative S-100β levels, an indicator of cerebral injury, was significantly lower in the off-pump CABG group compared to the other two groups (p<0.05). CONCLUSION: We found that off-pump coronary artery bypass grafting had less negative effects on inflammatory response and central nervous system compared to pulsatile cardiopulmonary bypass and non-pulsatile cardiopulmonary bypass techniques.
Authors:
H Bayram; D Erer; E Iriz; M H Zor; O Gulbahar; M E Ozdogan
Related Documents :
15353867 - Procedural results and distal embolization after saphenous vein graft stenting and angi...
2049887 - Initial clinical results with the wiktor stent: a new balloon-expandable coronary stent.
9013907 - Results of percutaneous transluminal angioplasty for atherosclerotic renal artery steno...
10467067 - Focal wall overstretching after high-pressure coronary stent implantation does not infl...
3058627 - Interactive effects on renal function between renal ischemia and intravascular contrast...
10643187 - A comparative study of balloon mitral valvuloplasty and closed mitral commissurotomy in...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-10-17
Journal Detail:
Title:  Perfusion     Volume:  -     ISSN:  1477-111X     ISO Abbreviation:  -     Publication Date:  2011 Oct 
Date Detail:
Created Date:  2011-10-18     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8700166     Medline TA:  Perfusion     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Cardiovascular Surgery, Gazi University Faculty of Medicine, Ankara, Turkey.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The successful use of cardiopulmonary support for a transected bronchus.
Next Document:  Does 6% hydroxyethyl starch 130/0.4 impact differently on blood glucose than 4% gelatine in patients...