Comparison of different techniques to measure air leaks during CPAP treatment in neonates.
MedLine Citation:
PMID:  18554973     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Continuous positive airway pressure (CPAP) is routinely used for respiratory support in neonates. Air leaks are not uncommon and can hinder treatment. This study compared leak flow data obtained using different leak definitions through modeling and in vitro measurements. METHODS: Using a computer simulation of an ideal CPAP system, the relationship between leak flow and three leak definitions was investigated. The leak flow was based on the measured inspiratory, expiratory and averaged breathing flow as commonly used in neonates. The theoretical results were compared with in vitro measurements using a commercial CPAP device for neonates (Leoni, Heinen & Löwenstein, Germany). Spontaneous breathing was simulated using a mechanical lung model, and defined air leaks were simulated using open silicone tubes of different lengths. RESULTS: Computer simulations showed that leak calculations were affected by leak flow and breathing pattern, and that the relationships were mostly non-linear. There were large differences in the results between the three leak definitions. The in vitro measurements correlated strongly with the theoretical modeling results. The derived numerical volume correction reduced the leak-dependent volume error in the mean (S.D.) to -1.6 (4.6)%. CONCLUSION: It is difficult to compare different measuring conditions and different CPAP devices due to the variation in results depending on the leak definition and the breathing pattern. Leak flow displays would provide superior air leak monitoring.
Authors:
G Schmalisch; H Fischer; C C Roehr; H Proquitté
Related Documents :
8306553 - Rates of change in peak expiratory flow and in diurnal variation in peak flow in patien...
6213383 - An assessment of three portable peak flow meters.
12187343 - Hemodynamic changes of the hand after radial forearm flap harvesting.
Publication Detail:
Type:  Comparative Study; Journal Article     Date:  2008-06-12
Journal Detail:
Title:  Medical engineering & physics     Volume:  31     ISSN:  1350-4533     ISO Abbreviation:  Med Eng Phys     Publication Date:  2009 Jan 
Date Detail:
Created Date:  2008-12-30     Completed Date:  2009-03-04     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9422753     Medline TA:  Med Eng Phys     Country:  England    
Other Details:
Languages:  eng     Pagination:  124-30     Citation Subset:  IM    
Affiliation:
Clinic of Neonatology (Charité), Universitätsmedizin Berlin, Charitéplatz 1, D-10117 Berlin, Germany. gerd.schmalisch@charite.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Air / analysis*
Computer Simulation
Humans
Infant, Newborn
Reproducibility of Results
Respiration, Artificial / instrumentation*,  methods*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Iron regulated genes of Salmonella enterica serovar Typhimurium in response to norepinephrine and th...
Next Document:  A probability density function method for detecting atrial fibrillation using R-R intervals.