Document Detail


Comparison of cardiovascular responses to airway management: fiberoptic intubation using a new adapter, laryngeal mask insertion, or conventional laryngoscopic intubation.
MedLine Citation:
PMID:  7772352     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
STUDY OBJECTIVES: To evaluate the circulatory effects of fiberoptic intubation with a newly developed mask adapter and to compare these effects with those obtained with a conventional laryngoscope and laryngeal mask airway with general anesthesia. DESIGN: Randomized study. SETTING: Operating room at a university hospital. PATIENTS: 30 ASA physical status I adult patients scheduled for minor elective surgery. INTERVENTIONS: A Macintosh laryngoscope was used for intubation in Group L (n = 10), a fiberoptic bronchoscope with newly developed mask adapter was used in Group FI (n = 10), and a laryngeal mask airway was used in Group LMA (n = 10). Anesthesia was induced with thiamylal, fentanyl, and vecuronium. Patients were manually ventilated for 4 minutes with sevoflurane. Then their tracheas were intubated with a laryngoscope or fiberoptic bronchoscope, or a laryngeal mask airway was inserted. MEASUREMENTS AND MAIN RESULTS: Blood pressure (BP) and heart rate (HR) were measured continuously. After intubation, the magnitude of change of both BP and HR was greatest in Group L, next highest in Group FI, and lowest in Group LMA. CONCLUSION: Fiberoptic intubation with general anesthesia using the newly developed mask adapter offers an advantage over the standard laryngoscope for patients in whom pressor response of intubation is potentially hazardous.
Authors:
M Imai; C Matsumura; Y Hanaoka; O Kemmotsu
Publication Detail:
Type:  Clinical Trial; Comparative Study; Journal Article; Randomized Controlled Trial    
Journal Detail:
Title:  Journal of clinical anesthesia     Volume:  7     ISSN:  0952-8180     ISO Abbreviation:  J Clin Anesth     Publication Date:  1995 Feb 
Date Detail:
Created Date:  1995-07-13     Completed Date:  1995-07-13     Revised Date:  2008-11-21    
Medline Journal Info:
Nlm Unique ID:  8812166     Medline TA:  J Clin Anesth     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  14-8     Citation Subset:  IM    
Affiliation:
Department of Anesthesiology, Hokkaido University School of Medicine, Sapporo, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Anesthesia, Inhalation
Anesthesia, Intravenous
Blood Pressure / physiology*
Carbon Dioxide / blood
Equipment Design
Female
Fiber Optic Technology / instrumentation
Heart Rate / physiology*
Humans
Intubation, Intratracheal / instrumentation*
Laryngeal Masks*
Laryngoscopes*
Male
Masks*
Middle Aged
Surgical Procedures, Elective
Surgical Procedures, Minor
Chemical
Reg. No./Substance:
124-38-9/Carbon Dioxide

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Parturient's posture during epidural puncture affects the distance from skin to epidural space.