Document Detail


Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise.
MedLine Citation:
PMID:  22234400     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Bioreactance is a novel non-invasive method for cardiac output measurement that involves the analysis of blood flow-dependent changes in the phase shifts of electrical currents applied across the chest. The present study (1) compared resting and exercise cardiac outputs determined by bioreactance and bioimpedance methods and those estimated from measured oxygen consumption, (2) determined the relationship between cardiac output and oxygen consumption, and (3) assessed the agreement between the bioreactance and bioimpedance methods. Twelve healthy subjects (aged 30 ± 4 years) performed graded cardiopulmonary exercise test on a recumbent cycle ergometer on two occasions, 1 week apart. Cardiac output was monitored at rest, at 30, 50, 70, 90, 150 W and at peak exercise intensity by bioreactance and bioimpedance and expired gases collected. Resting cardiac output was not significantly different between the bioreactance and bioimpedance methods (6.2 ± 1.4 vs. 6.5 ± 1.4 l min(-1), P = 0.42). During exercise cardiac outputs were correlated with oxygen uptake for both bioreactance (r = 0.84, P < 0.01) and bioimpedance techniques (r = 0.82, P < 0.01). At peak exercise bioimpedance estimated significantly lower cardiac outputs than both bioreactance and theoretically calculated cardiac output (14.3 ± 2.6 vs. 17.5 ± 5.2 vs. 16.9 ± 4.9 l min(-1), P < 0.05). Bland-Altman analyses including data from rest and exercise demonstrated that the bioimpedance method reported ~1.5 l min(-1) lower cardiac output than bioreactance with lower and upper limits of agreement of -2.98 to 5.98 l min(-1). Bioimpedance and bioreactance methods provide different cardiac output estimates, particularly at high exercise intensity, and therefore the two methods cannot be used interchangeably. In contrast with bioimpedance, bioreactance cardiac outputs are similar to those estimated from measured oxygen consumption.
Authors:
Djordje G Jakovljevic; Sarah Moore; Kate Hallsworth; Gulnar Fattakhova; Christian Thoma; Michael I Trenell
Publication Detail:
Type:  Comparative Study; Journal Article     Date:  2012-01-11
Journal Detail:
Title:  Journal of clinical monitoring and computing     Volume:  26     ISSN:  1573-2614     ISO Abbreviation:  J Clin Monit Comput     Publication Date:  2012 Apr 
Date Detail:
Created Date:  2012-03-14     Completed Date:  2012-07-27     Revised Date:  2014-03-14    
Medline Journal Info:
Nlm Unique ID:  9806357     Medline TA:  J Clin Monit Comput     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  63-8     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Cardiac Output / physiology*
Cardiography, Impedance / methods*
Exercise / physiology*
Exercise Test
Female
Humans
Male
Monitoring, Physiologic / methods*
Oxygen Consumption / physiology
Rest / physiology*
Grant Support
ID/Acronym/Agency:
G0700718//Medical Research Council; G0900686//Medical Research Council; MC_G0802536//Medical Research Council; SRF-2011-04-017//Department of Health

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Physically active men show better semen parameters and hormone values than sedentary men.
Next Document:  Coordinate-bond-dependent solid-phase organic synthesis of biotinylated desferrioxamine B: a new rou...