Comparison of a calixarene-based ion-selective electrode with two automated analyzers for the clinical determination of sodium in blood plasma.
MedLine Citation:
PMID:  2100609     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Neutral-carrier ion-selective electrodes based on methyl p-t-butylcalix[4]aryl acetate have been prepared that are responsive to sodium ions. The miniaturized catheter-type electrodes were obtained by dip-coating their porcelain tips in a PVC membrane cocktail. Examination of the general performance of the electrodes revealed excellent characteristics in terms of Nernstian response, selectivity, stability, reproducibility and response time. The results from the indirect potentiometric assessment of a large number of plasma samples with the electrodes showed a good correlation with the results from two automated analyzers (Technicon Smac 3, Hitachi 704) and with flame photometric data. Although inconsistencies were observed in the measurement of some plasma samples, the variance seemed to be method-dependent, and the overall performance of the electrodes showed promise as an alternative to the sodium glass electrode. Some factors influencing the standard potential of the measuring cell are discussed as a source of error.
Authors:
M Telting-Diaz; F Regan; D Diamond; M R Smyth
Related Documents :
16317899 - Preparation of a clay-modified carbon paste electrode based on 2-thiazoline-2-thiol-hex...
18699409 - Cooling of extraction electrode of an ion source in long-pulse operation.
18970229 - Cs+ -selective membrane electrodes based on ethylene glycol-functionalized polymeric mi...
16365779 - Optimizing the analytical performance and construction of ion-selective electrodes with...
18329719 - Development of potentiometric urea biosensor based on urease immobilized in pva-paa com...
19067579 - Ion channel mimetic chronopotentiometric polymeric membrane ion sensor for surface-conf...
698219 - Cholesterol-lipid interactions in membranes. the saturation concentration of cholestero...
12527059 - In vitro survival of bovine spermatozoa stored at room temperature under epididymal con...
20189719 - Two-dimensional ordering of pentafluorobenzenethiol self-assembled monolayers on au(111...
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Journal of pharmaceutical and biomedical analysis     Volume:  8     ISSN:  0731-7085     ISO Abbreviation:  J Pharm Biomed Anal     Publication Date:  1990  
Date Detail:
Created Date:  1991-08-26     Completed Date:  1991-08-26     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8309336     Medline TA:  J Pharm Biomed Anal     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  695-700     Citation Subset:  IM    
Affiliation:
School of Chemical Sciences, Dublin City University, Ireland.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Autoanalysis
Calixarenes
Electrodes
Humans
Macromolecular Substances
Membranes, Artificial
Sodium / blood*
Chemical
Reg. No./Substance:
0/Macromolecular Substances; 0/Membranes, Artificial; 130036-26-9/Calixarenes; 7440-23-5/Sodium

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Validation of a radioimmunoassay for the determination of human plasma concentrations of lamotrigine...
Next Document:  Potentiometric investigation of the stability of palladium(II) complex of pralidoxime chloride in aq...