Document Detail


Comparison between echo contrast agent-specific imaging modes and perfusion-weighted magnetic resonance imaging for the assessment of brain perfusion.
MedLine Citation:
PMID:  12364734     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND AND PURPOSE: Contrast burst imaging (CBI) and time variance imaging (TVI) are new ultrasonic imaging modes enabling the visualization of intravenously injected echo contrast agents in brain parenchyma. The aim of this study was to compare the quantitative ultrasonic data with corresponding perfusion-weighted MRI data (p-MRI) with respect to the assessment of brain perfusion. METHODS: Twelve individuals with no vascular abnormalities were examined by CBI and TVI after an intravenous bolus injection of 4 g galactose-based microbubble suspension (Levovist) in a concentration of 400 mg/mL. Complementary, a dynamic susceptibility contrast MRI, ie, p-MRI, of each individual was obtained. In both ultrasound (US) methods and p-MRI, time-intensity curves were calculated offline, and absolute time to peak intensities (TPI), peak intensities (PI), and peak width (PW) of US investigations and TPI, relative cerebral blood flow (CBF) and relative cerebral blood volume (CBV) of p-MRI examinations were determined in the following regions of interest (ROIs): lentiform nucleus (LN), white matter (WM), posterior (PT), and anterior thalamus (AT). In addition, the M(2) segment of the middle cerebral artery (MCA) was evaluated in the US, and the precentral gyrus (PG) was examined in the p-MRI examinations. In relation to a reference parenchymal ROI (AT), relative TPIs were compared between the US and p-MRI methods and relative PI of US investigations with the ratio of CBF (rCBF) of p-MRI examinations in identical ROIs. RESULTS: Mean TPIs varied from 18.3+/-5.0 (AT) to 20.1+/- 5.8 (WM) to 17.2+/-4.9 (MCA) seconds in CBI examinations and from 19.4+/-5.3 (AT) to 20.4+/-4.3 (WM) to 17.3+/-4.0 (MCA) seconds in TVI examinations. Mean PIs were found to vary from 581.9+/-342.4 (WM) to 1522.9+/-574.2 (LN) to 3400.9+/- 621.7 arbitrary units (MCA) in CBI mode and from 7.5+/-4.6 (WM) to 17.5+/-4.9 (LN) to 46.3+/-7.1 (MCA) arbitrary units in TVI mode. PW ranged from 7.3+/-4.5 (AT) to 9.1+/-4.0 (LN) to 24.3+/-12.8 (MCA) seconds in CBI examinations and from 7.1+/-3.9 (AT) to 8.7+/-3.5 (LN) to 26.7+/-18.2 (MCA) seconds in TVI examinations. Mean TPI was significantly shorter and mean PI and mean PW were significantly higher in the MCA compared with all other ROIs (P<0.05). Mean TPI of the p-MRI examinations ranged from 22.0+/-6.9 (LN) to 23.0+/-6.8 (WM) seconds; mean CBF ranged from 0.0093+/- 0.0041 (LN) to 0.0043+/-0.0021 (WM). There was no significant difference in rTPI in any ROI between US and p-MRI measurements (P>0.2), whereas relative PIs were significantly higher in areas with lower insonation depth such as the LN compared with rCBF. CONCLUSIONS: In contrast to PI, TPI and rTPI in US techniques are robust parameters for the evaluation of cerebral perfusion and may help to differentiate physiological and pathological perfusion in different parenchymal regions of the brain.
Authors:
Saskia H Meves; Wilko Wilkening; Tammo Thies; Jens Eyding; Thilo Hölscher; Michael Finger; Gebhard Schmid; Helmut Ermert; Thomas Postert;
Related Documents :
3471364 - A simplified method of xenon-enhanced ct for regional cerebral blood flow (rcbf) measur...
20573464 - Reliability and reproducibility of perfusion mri in cognitively normal subjects.
3588894 - Moyamoya disease: mr imaging.
18035284 - Computer-aided diagnosis scheme for detection of lacunar infarcts on mr images.
7920084 - Hypomelanosis of ito associated with west syndrome: report of a case.
20152274 - Optimal reconstructed section thickness for the detection of liver lesions with multide...
Publication Detail:
Type:  Clinical Trial; Comparative Study; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Stroke; a journal of cerebral circulation     Volume:  33     ISSN:  1524-4628     ISO Abbreviation:  Stroke     Publication Date:  2002 Oct 
Date Detail:
Created Date:  2002-10-04     Completed Date:  2002-11-25     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0235266     Medline TA:  Stroke     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2433-7     Citation Subset:  IM    
Affiliation:
Department of Neurology, Ruhr University, Bochum, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Brain / blood supply*
Cerebrovascular Circulation*
Contrast Media*
Echoencephalography / methods*
Female
Humans
Image Interpretation, Computer-Assisted
Magnetic Resonance Imaging / methods*
Male
Middle Aged
Reference Values
Reproducibility of Results
Chemical
Reg. No./Substance:
0/Contrast Media

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Comparison of CT and CT angiography source images with diffusion-weighted imaging in patients with a...
Next Document:  Effect of intravenous thrombolysis on MRI parameters and functional outcome in acute stroke <6 hours...