Comparison of the automated non-invasive oscillometric blood pressure monitor (BpTRU) with the auscultatory mercury sphygmomanometer in a paediatric population.
MedLine Citation:
PMID:  15021077     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: To directly compare the accuracy of the BpTRU (an automated oscillometric blood pressure device) with standard auscultatory mercury sphygmomanometry in a pediatric population. DESIGN: The BpTRU was connected in parallel with a standard mercury sphygmomanometer. Two observers measured the blood pressures at the same time as it was being measured by the BpTRU. The observers and the BpTRU were all blinded from each other. METHODS: For each of the demographic data--subject age, sex and arm sizes--the mean, standard deviation (SD) and range was calculated. The difference between the mean BpTRU and the standard reference measurements (observer average) was calculated with SD and ranges. The percentage of measurements within 5, 10 and 15 mmHg agreement was expressed. RESULTS: From the 36 subjects recruited aged 3-18 years, 162 pairs of sitting blood pressures were included. The difference between the mean BpTRU readings and the reference standard measurements (as determined by the observers) was 1.45+/-5.67 mmHg for systolic blood pressures, and -3.24+/-7.39 mmHg for diastolic pressure and 0.20+/-2.47 bpm for heart rate. CONCLUSION: The BpTRU is of similar accuracy in measuring blood pressure in children as it was in an adult population.
Authors:
Gurdial S Mattu; Balraj S Heran; James M Wright
Related Documents :
3579197 - Radionuclide angiography in the assessment of lumbar sympathectomy.
509047 - Plasma exchange and raynaud's phenomenon--its assessment by doppler ultrasound velocime...
7804947 - Errors in assessment of blood pressure: sphygmomanometers and blood pressure cuffs.
2068557 - Diagnostic value of finger systolic blood pressure in the assessment of vasospastic rea...
19878017 - Effect of intravenous administration of lactated ringer's solution or hetastarch for th...
7894357 - Sigmoidal curve-fitting of baroreceptor sensitivity in renovascular 2k1c hypertensive r...
Publication Detail:
Type:  Comparative Study; Evaluation Studies; Journal Article    
Journal Detail:
Title:  Blood pressure monitoring     Volume:  9     ISSN:  1359-5237     ISO Abbreviation:  Blood Press Monit     Publication Date:  2004 Feb 
Date Detail:
Created Date:  2004-03-15     Completed Date:  2004-10-19     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9606438     Medline TA:  Blood Press Monit     Country:  England    
Other Details:
Languages:  eng     Pagination:  39-45     Citation Subset:  IM    
Affiliation:
Department of Pharmacology & Therapeutics, University of British Columbia, Vancouver, BC, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Age Factors
Automation
Blood Pressure
Blood Pressure Determination / instrumentation*,  standards
Blood Pressure Monitors / standards*
Child
Child, Preschool
Humans
Oscillometry
Reproducibility of Results
Sphygmomanometers / standards

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Clinical evaluation of an automated oscillometric blood pressure wrist device.
Next Document:  Overall accuracy of the BpTRU--an automated electronic blood pressure device.