BACKGROUND AND STUDY AIMS:There is a paucity of in vitro methods for evaluating ERCP accessories. We hypothesize that the time taken to perform a simulated single stent or multiple stents placement is different for stenting systems with or without the capability of intraductal ductal release (IDR) of the guide wire. PATIENTS AND METHODS:We conducted an un-blinded in vitro comparison of ERCP accessories using a mechanical simulator during hands-on ERCP practice workshops. A total of 21 U.S. participants and 20 Chinese participants with various level of ERCP experience took part in the different practice workshops. Accessories with and without the capability of intraductal release of guide wire were compared. Total time required for completing a simulated stenting procedure with single or multiple stents and the respective simulated fluoroscopy time were recorded. RESULTS:There was no significant difference in the time taken for placement of a single stent using either stenting systems. Stenting system capable of intraductal release of the guide wire required significantly shorter time to complete placement of three stents. CONCLUSIONS:Using time required to complete a specific task, i. e. biliary stenting, the mechanical simulator permits the performance of different accessories by the same group of operators to be evaluated objectively. |
| | |
Authors:
|
J W Leung; W Lee; R Wilson; B S Lim; F W Leung |
Related Documents
:
|
15783099 - Confirmation of the correct placement of lower end of dj stent during open surgery: poi... 9234139 - Angioscopic evaluation of an endoluminal aortic graft: the first clinical experience. 17323299 - Endovascular treatment of tumor-induced axillary artery hemorrhage. 1933639 - Balloon expandable stents for acute closure post failed coronary angioplasty: case repo... 11553949 - Deep intubation of 8 fr guiding catheter to deliver coronary stent graft to seal corona... 17126169 - Teflon felt wrapping repair for coronary perforation after failed angioplasty. 11382719 - Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocard... 7931589 - Cerebral damage caused by interrupted, repeated arterial occlusion versus uninterrupted... 9213029 - Efficacy of low-molecular-weight heparin delivery with the dispatch catheter following ... |
Publication Detail:
|
Type: Comparative Study; In Vitro; Journal Article; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, Non-P.H.S. Date: 2008-12-08 |
Journal Detail:
|
Title: Endoscopy Volume: 40 ISSN: 1438-8812 ISO Abbreviation: Endoscopy Publication Date: 2008 Dec |
Date Detail:
|
Created Date: 2008-12-09 Completed Date: 2009-03-23 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 0215166 Medline TA: Endoscopy Country: Germany |
Other Details:
|
Languages: eng Pagination: 983-8 Citation Subset: IM |
Affiliation:
|
Section of Gastroenterology, Sacramento Veterans Affairs Medical Center, Veterans Affairs Northern California Healthcare System, Mather, California 95655, USA. jwleung@ucdavis.edu |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Attitude of Health Personnel Cholangiopancreatography, Endoscopic Retrograde / instrumentation* Cholestasis, Extrahepatic / diagnosis, therapy Common Bile Duct Diseases / diagnosis, therapy Curriculum Education Equipment Design Fellowships and Scholarships Fluoroscopy / instrumentation Gastroenterology / education Humans Models, Anatomic* Questionnaires Stents Time and Motion Studies |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Wireless therapeutic endoscopic capsule: in vivo experiment.
Next Document: Histopathology of Barrett's esophagus after ablation and endoscopic mucosal resection therapy.