Document Detail


Comparison of V-Loc™ 180 wound closure device and Quill™ PDO knotless tissue-closure device for intradermal closure in a porcine in vivo model: Evaluation of biomechanical wound strength.
MedLine Citation:
PMID:  22287058     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE: The objective of this study was to compare the biomechanical strength of two barbed suture devices: V-Loc™ 180 Wound Closure Device and Quill™ PDO Knotless Tissue-Closure Device following primary cosmetic skin closures in a porcine dermal model. METHOD: This prospective randomized, controlled in vivo trial compared size 3/0 V-Loc™ 180 device to size 2/0 Quill™ PDO device. Both products were tested for dermal closure in adult porcine models and evaluated at five timepoints. At postoperative days 0, 3, 7, 14, and 28 sutured tissue regions were excised post mortem and tested for intradermal wound holding strength. RESULTS: Wounds closed with V-Loc™ 180 device were stronger than Quill™ PDO device at days 0, 3, 7, and 14 with these differences being significant (p < 0.05) at days 3 and 7. At day 3, the average maximum load of V-Loc™ 180 was 13.53 kgf and Quill™ PDO was 10.38 kgf (p = 0.002). At day 7, the average maximum load of V-Loc™ 180 was 10.4 kgf and Quill™ PDO was 7.56 kgf (p = 0.001). Throughout the duration of the study, there was no suture extrusion or tissue distortion and all wounds healed with no major complications. CONCLUSIONS: In this study, V-Loc™ 180 device was significantly stronger than Quill™ PDO device during the critical phases of wound healing in skin. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2012.
Authors:
Kristen Gingras; Jeffrey Zaruby; Don Maul
Related Documents :
17476038 - The safety of a bivalirudin-based approach in patients undergoing rotational atherectomy.
10069758 - Long-term prophylaxis in venous thromboembolism: lmwh or oral anticoagulation?
6662638 - Low-dose heparin prophylaxis and postoperative wound hematoma.
19777388 - Clinical presentation and long-term outcome of cerebral venous thrombosis.
11448018 - Analgesic effect of etidronate on degenerative joint disease.
16278638 - Is carotid endarterectomy in octogenarians more dangerous than in younger patients?
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-1-30
Journal Detail:
Title:  Journal of biomedical materials research. Part B, Applied biomaterials     Volume:  -     ISSN:  1552-4981     ISO Abbreviation:  -     Publication Date:  2012 Jan 
Date Detail:
Created Date:  2012-1-30     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101234238     Medline TA:  J Biomed Mater Res B Appl Biomater     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2012 Wiley Periodicals, Inc.
Affiliation:
Covidien Surgical Devices, 60 Middletown Ave, North Haven, Connecticut 06473. Kristen.Gingras@covidien.com.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A Leak in the Lung: Endobronchial One-Way Valve Placement as Treatment for a Persistent Bronchopleur...
Next Document:  Hypoxia upregulates ovarian cancer invasiveness via the binding of HIF-1? to a hypoxia-induced, meth...