| Comparison of the SphygmoCor and Omron devices in the estimation of pressure amplification against the invasive catheter measurement. | |
| | |
MedLine Citation:
|
PMID: 23188416 Owner: NLM Status: Publisher |
Abstract/OtherAbstract:
|
BACKGROUND:: We previously tested the accuracy of the SphygmoCor and Omron HEM-9000AI devices in the estimation of central blood pressure. In the present study, we investigated these two devices in the estimation of central-to-brachial pressure amplification against the invasive catheter measurement. METHODS:: In 33 individuals undergoing cardiac catheterization, we measured central blood pressure simultaneously by the invasive catheter and each of the two noninvasive devices and brachial blood pressure by the invasive catheter and an automated oscillometric blood pressure monitor of the Omron device. Pressure amplification was calculated as central-to-brachial systolic pressure difference and pulse pressure difference and ratio. The agreement between each of these two noninvasive devices and the invasive catheter was evaluated using the Student's t-test, intraclass correlation analysis, and the Bland-Altman method. RESULTS:: The mean central-to-brachial systolic pressure difference and pulse pressure difference and ratio estimated by Omron were significantly lower than those measured by the catheter (P < 0.001), whereas no difference was observed for SphygmoCor (P ≥ 0.07). Nonetheless, the intraclass correlation coefficients for systolic pressure difference and pulse pressure difference and ratio between the noninvasive and invasive catheter measurements were similar for the two devices, being 0.11 (P = 0.56), 0.38 (P = 0.03), and 0.40 (P = 0.02), respectively, for SphygmoCor, and 0.15 (P = 0.41), 0.23 (P = 0.20), and 0.53 (P = 0.002), respectively, for Omron. CONCLUSION:: If the invasive catheter measurement would be considered as standard, the two noninvasive devices have similar accuracy in the estimation of pressure amplification, but apparently require device-specific criteria for diagnosis. Pulse pressure ratio seems to be a more consistent measure of central-to-brachial pressure amplification. |
| | |
Authors:
|
Feng-Hua Ding; Yan Li; Rui-Yan Zhang; Qi Zhang; Ji-Guang Wang |
Related Documents
:
|
1681746 - Pressure diuresis and autonomic function in conscious dogs. 1390326 - Antihypertensive efficacy and effects of nitrendipine on cardiac and renal hemodynamics... 1636746 - Renal kinin antagonism does not impair pressure-induced natriuresis. 2929066 - Reversible renal hypertension due to renal hygroma. 53446 - Mass screening for hypertension in copenhagen supermarkets. 1451156 - Imipramine induced heart failure in the dog: a model to study the effect of cardiac ass... |
Publication Detail:
|
Type: JOURNAL ARTICLE Date: 2012-11-23 |
Journal Detail:
|
Title: Journal of hypertension Volume: - ISSN: 1473-5598 ISO Abbreviation: J. Hypertens. Publication Date: 2012 Nov |
Date Detail:
|
Created Date: 2012-11-28 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 8306882 Medline TA: J Hypertens Country: - |
Other Details:
|
Languages: ENG Pagination: - Citation Subset: - |
Affiliation:
|
aCentre for Epidemiological Studies and Clinical Trials, The Shanghai Institute of Hypertension bDepartment of Cardiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Assessment of the selection process for myocutaneous flap repair and surgical complications in pelvi...
Next Document: Blood pressure trends and mortality: the Leiden 85-plus Study.