| Comparison of B-mode and conventional colour/power Doppler ultrasound, contrast-enhanced Doppler ultrasound and spiral CT in the diagnosis of focal lesions of the liver: Results of a multicentre study. | |
| | |
MedLine Citation:
|
PMID: 12226762 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
AIM: In patients with lesions of the liver we compared diagnoses based on different methods of ultrasound as well as spiral CT with the final diagnosis reached at the time of the patient's discharge from hospital. METHOD: From records of a prospective multicentre study including 90 liver lesions investigated with B-mode baseline and conventional colour/power Doppler ultrasound, contrast-enhanced colour/power Doppler ultrasound and spiral-CT, we evaluated only those where diagnoses for all modalities were available, and where the diagnosis at discharge comprising all clinical, laboratory and imaging data as well as histologic proof was at least "highly probable". RESULTS: 60 lesions met the inclusion criteria. 20 lesions were ultimately diagnosed as benign, and 40 as malignant. With respect to the diagnosis of malignancy, sensitivity was 92.5 % (37/40) with B-mode and unenhanced conventional colour/power Doppler US ultrasound, 97.5 % (39/40) with contrast-enhanced colour/ power Doppler ultrasound, and 100 % with CT; the corresponding specificities were 65 % (13/20), 85 % (17/20) and 80 % (16/20). 4 of 7 false positive, and 2 of 3 false negative results in the unenhanced technique were diagnosed correctly with contrast-enhanced Doppler ultrasound. CONCLUSION: Compared to conventional ultrasound, contrast-enhanced Doppler ultrasound improved the diagnostic accuracy in 10 % of the cases. Its accuracy in our study was equal to that of CT. |
| | |
Authors:
|
M Beissert; S Delorme; S Mutze; W R Lees; M L Bahner; S Filimonow; A R Gillams; I Zuna; A Bauer; M Jenett |
Publication Detail:
|
Type: Comparative Study; Journal Article; Multicenter Study; Research Support, Non-U.S. Gov't |
Journal Detail:
|
Title: Ultraschall in der Medizin (Stuttgart, Germany : 1980) Volume: 23 ISSN: 0172-4614 ISO Abbreviation: Ultraschall Med Publication Date: 2002 Aug |
Date Detail:
|
Created Date: 2002-09-12 Completed Date: 2002-11-20 Revised Date: 2006-11-15 |
Medline Journal Info:
|
Nlm Unique ID: 8303585 Medline TA: Ultraschall Med Country: Germany |
Other Details:
|
Languages: eng Pagination: 245-50 Citation Subset: IM |
Affiliation:
|
Dept. of Radiology, University of Würzburg, Würzburg, Germany. beissert@roentgen.uni-wuerzburg.de |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Contrast Media Echocardiography, Doppler, Color / methods Humans Image Processing, Computer-Assisted Liver Neoplasms / classification, radiography, ultrasonography* Reproducibility of Results Sensitivity and Specificity Ultrasonography, Doppler, Color / methods* |
| Chemical | |
Reg. No./Substance:
|
0/Contrast Media |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Epiploic appendagitis: sonographic findings in 28 cases
Next Document: Endobronchial ultrasound for local tumour and lymph node staging in patients with centrally growing ...