Comparative study of normal and rough human skin hydration in vivo: evaluation with four different instruments.
MedLine Citation:
PMID:  2064999     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Appropriate monitoring of skin hydration during clinical and/or experimental trials needs devices with acceptable reproducibility and sensitivity under conditions ranging from increased, and normal to low hydration. The aim of this study was to compare the variation of electrometric data generated by 4 different instruments (Skicon Hygrometer, 2 CM420 and a CM820 corneometer) in normal and experimentally damaged skin displaying surface roughness. Rough skin sites were observed during the healing process after repeated tape stripping of stratum corneum in humans (e.g. 10-14 days after insult). They displayed lower conductance and or capacitance levels as compared to normal skin sites of the same subjects. The Skicon hygrometer showed higher variability as compared to the corneometers and was less sensitive, in relative terms, in the rough skin sites. This device also showed a moderate zero drift and re-zeroing was repeatedly utilized during the experiment. When the corneometer data were plotted against the hygrometer data, the slope of the regression line generated by the CM420a was different from CM420b and from CM820; the two latter were not significantly different from each other. Hence, comparison of absolute data obtained under comparable conditions (in this case CM420a and CM420b) in a single laboratory should not be made without prior calibration. Standards for evaluating interinstrumental variation are currently unavailable. This aspect of the measurement of electrical properties of the skin has not been investigated in great detail and has often been neglected in the past. Our findings also indicate that a constant control over the performances of a particular device should further improve the reliability of the data.
Authors:
D Van Neste
Related Documents :
17654559 - Comparative efficacy of repetitive nerve stimulation, exercise, and cold in differentia...
1489989 - Real-time measurement of microcirculation of skin by reflectance spectrophotometry.
1451459 - Monitoring of skin response to sodium lauryl sulphate: clinical scores versus bioengine...
16892629 - Enhanced cold and desiccation tolerance in diapausing adults of culex pipiens, and a ro...
11770639 - Broiler carcass contamination with campylobacter from feces during defeathering.
21423729 - Beaked whales respond to simulated and actual navy sonar.
20622139 - Nitrogen balance in older individuals in energy balance depends on timing of protein in...
21226819 - Exercise training improves physical fitness and vascular function in children with type...
2436139 - Intracellular ph in the rat mandibular salivary gland: the role of na-h and cl-hco3 ant...
Publication Detail:
Type:  Clinical Trial; Comparative Study; Controlled Clinical Trial; Journal Article    
Journal Detail:
Title:  Journal of dermatological science     Volume:  2     ISSN:  0923-1811     ISO Abbreviation:  J. Dermatol. Sci.     Publication Date:  1991 Mar 
Date Detail:
Created Date:  1991-08-14     Completed Date:  1991-08-14     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  9011485     Medline TA:  J Dermatol Sci     Country:  NETHERLANDS    
Other Details:
Languages:  eng     Pagination:  119-24     Citation Subset:  IM    
Affiliation:
Skin Study Center, Skinterface SPRL, Tournai, Belgium.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Analysis of Variance
Body Water / metabolism*
Electrophysiology / instrumentation*
Female
Humans
Reference Values
Skin / injuries*,  metabolism
Wound Healing / physiology*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Reintroduction of a normal retinoblastoma gene into retinoblastoma and osteosarcoma cells inhibits t...
Next Document:  Intranuclear androgen concentrations in facial skin.