OBJECTIVE: The purpose of this study was to evaluate the detection of intravascular injection or hematic aspiration in relation to (a) the particular combination of syringe system and needle (there being 3 different syringe systems [2 self-aspirating and 1 non-self-aspirating] and 3 different needles); (b) the anesthetic technique used (direct or indirect) to induce inferior alveolar nerve block; (c) patient sex; and (d) the operator performing the block. STUDY DESIGN: Two operators performed 246 inferior alveolar nerve blocks (on 90 male and 156 female patients) using 3 syringe systems (1 non-self-aspirating (Uniject K) and 2 self-aspirating (Aspiject and Inibsaject)) and 3 types of needle in terms of length and gauge combination (30G/25 mm, 27G/25 mm, and 27G/35 mm) for conventional and surgical extractions of lower third molars. Three aspirations were made at each of 3 different times in each block. Hematic aspiration was accepted only if a blood jet rose forcefully along the cartridge on aspiration. In each block, the age and sex of the patient was recorded, along with the latency or time elapsed from introduction of the anesthetic solution to onset of the anesthetic effect, the depth of the needle at contact with the mandibular ramus, and the operator performing the block. RESULTS: Significant differences (P <.05) were observed with respect to hematic aspiration and the syringe system used, the Uniject K system yielding higher percentage hematic aspirations (5.69%) than either of the self-aspirating systems, Inibsaject (2.03%) and Aspiject (1. 21%). However, no significant differences (P >.05) were observed with respect to number of aspirations, needle length, needle gauge, anesthetic technique performed, patient's sex, or operator performing the inferior alveolar nerve block. The incidence of hematic aspirations was 8.9%. The mean latency time was 39.03 seconds, and the mean needle depth at contact with the mandibular ramus was 20.72 mm. CONCLUSIONS: The Uniject K non-self-aspirating syringe system was associated with a higher number of hematic aspirations than the self-aspirating systems (Inibsaject and Aspiject). However, the detection of hematic aspirations was not dependent on length or gauge of the needles used, anesthetic technique performed (direct or indirect), patient's sex, or operator who performed the block.
Authors:
E Delgado-Molina; S Bueno-Lafuente; L Berini-Aytés; C Gay-Escoda
Related Documents :
17303269 - Noncompaction and endocarditis in suspected mitochondrial disorder.
2427839 - Clinical cardiac electrophysiologic study of celiprolol.
7681169 - Rapid resolution of new right bundle branch block in acute anterior myocardial infarcti...
881609 - Cardiac abnormalities in a female patient with hypogonadotropic hypogonadism with anosmia.
9193039 - Abnormal ventricular repolarization mimicking myocardial infarction after heterocyclic ...
8247599 - Risk of cardiac dysrhythmias in chronic spinal cord injury patients.
22283829 - Overexpression of apolipoprotein b attenuates pathologic cardiac remodeling and hypertr...
16213219 - Moody encodes two gpcrs that regulate cocaine behaviors and blood-brain barrier permeab...
18215599 - Treatment delay in patients undergoing primary percutaneous coronary intervention for s...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics     Volume:  88     ISSN:  1079-2104     ISO Abbreviation:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod     Publication Date:  1999 Nov 
Date Detail:
Created Date:  1999-11-23     Completed Date:  1999-11-23     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  9508562     Medline TA:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  557-60     Citation Subset:  D; IM    
Affiliation:
University of Barcelona, Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Spain.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Adult
Aged
Anesthesia, Dental / instrumentation*
Blood
Equipment Design
Female
Humans
Male
Mandibular Nerve*
Middle Aged
Needles
Nerve Block / instrumentation*
Suction
Syringes*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Three-dimensional facial morphometric assessment of soft tissue changes after orthognathic surgery.
Next Document:  Hematologic abnormalities among HIV-infected patients: associations of significance for dentistry.