Combined ultrasound and fluorescence spectroscopy for physico-chemical imaging of atherosclerosis.
MedLine Citation:
PMID:  7868139     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
This paper describes a combined ultrasonic and spectroscopic system for remotely obtaining physico-chemical images of normal arterial tissue and atherosclerotic plaque. Despite variations in detector-tissue separation, R, fluorescence powers corresponding to pixels in the image are converted to the same set of calibrated units using distance estimations from A-mode ultrasound reflection times. An empirical model, validated by Monte Carlo simulations of light propagation in tissue, is used to describe changes in fluorescence power as a function of R. Fluorescence spectra of normal and atherosclerotic human aorta obtained with this system are presented as a function of R. To compensate for changes in fluorescence power with R, the empirical model was used in each case to calculate the fluorescence power at a constant reference value of R(Rref = 1.67 mm). Prior to compensation, tissue fluorescence power decreased more than a factor of two as R was increased from 2.5 to 5 mm. Following compensation, the fluorescence power varied less than +/- 10% of the average compensated peak. The chemical composition of each sample was determined by fitting its fluorescence spectrum (in calibrated units) to a model of tissue fluorescence incorporating structural protein and ceroid fluorescence, as well as structural protein and hemoglobin attenuation. Parameters of the fit were used to classify tissue type. Without compensation for distance variation, classification of tissue type was frequently incorrect; however, with compensation, predictive value was high. A 1-D chemical image of a section of human aorta containing both normal and atherosclerotic regions obtained with this system is also presented. After compensation for detector-sample separation, tissue classifications along the cross-section closely resemble those obtained from histology. Regions of elevated ceroid concentration and intimal thickening are clearly observable in the resultant chemical image. The potential value of this type of system in the diagnosis and treatment of coronary artery disease is discussed.
Authors:
S Warren; K Pope; Y Yazdi; A J Welch; S Thomsen; A L Johnston; M J Davis; R Richards-Kortum
Related Documents :
20886969 - Three-dimensional sliced fluorescence imaging in bulbs.
17559119 - Automated analysis of fish and immunohistochemistry images: a review.
19644259 - Quantitative assessment of perfusion and vascular compromise in perforator flaps using ...
19503759 - Miniaturized side-viewing imaging probe for fluorescence lifetime imaging (flim): valid...
18941899 - Development of microscopic systems for high-speed dual-excitation ratiometric ca2+ imag...
19142979 - Whole-body section fluorescence imaging--a novel method for tissue distribution studies...
19965169 - Electromagnetic forward and inverse problems of non-rotating magnetoacoustic tomography...
18451929 - Sparsity constrained regularization for multiframe image restoration.
20237649 - An integrated one-step system to extract, analyze and annotate all relevant information...
Publication Detail:
Type:  In Vitro; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  IEEE transactions on bio-medical engineering     Volume:  42     ISSN:  0018-9294     ISO Abbreviation:  IEEE Trans Biomed Eng     Publication Date:  1995 Feb 
Date Detail:
Created Date:  1995-03-30     Completed Date:  1995-03-30     Revised Date:  2009-11-11    
Medline Journal Info:
Nlm Unique ID:  0012737     Medline TA:  IEEE Trans Biomed Eng     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  121-32     Citation Subset:  IM    
Affiliation:
University of Texas at Austin, Biomedical Engineering Program 78712.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aorta / chemistry,  pathology,  ultrasonography
Calibration
Collagen / analysis
Coronary Artery Disease / pathology*,  ultrasonography*
Elastin / analysis
Humans
Image Processing, Computer-Assisted
Models, Cardiovascular
Monte Carlo Method
Predictive Value of Tests
Spectrometry, Fluorescence / instrumentation,  methods*
Ultrasonography / methods
Chemical
Reg. No./Substance:
9007-34-5/Collagen; 9007-58-3/Elastin

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Identification of two highly polymorphic CA-repeats (D21S1224 and D21S1261) on human chromosome 21q2...
Next Document:  A real-time electrical impedance tomography system for clinical use--design and preliminary results.