Document Detail


Color Doppler diagnosis of mechanical prosthetic mitral regurgitation: usefulness of the flow convergence region proximal to the regurgitant orifice.
MedLine Citation:
PMID:  2239666     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
In prosthetic or paravalvular prosthetic mitral regurgitation, transthoracic color Doppler flow mapping can sometimes fail to detect the regurgitant jet within the left atrium because of the shadowing by the prosthetic valve. To overcome this limitation, we assessed the utility of color Doppler visualization of the flow convergence region (FCR) proximal to the regurgitant orifice in 20 consecutive patients with mechanical prosthetic mitral regurgitation documented by surgery and cardiac catheterization (13 of 20 patients). In addition, we studied 33 patients with normally functioning mitral prostheses. Doppler studies were performed in the apical, subcostal, and parasternal long-axis views. An FCR was detected in 95% (19 of 20) of patients with prosthetic mitral regurgitation. A jet area in the left atrium was detected in 60% (12 of 20) of patients. In 18 of 19 patients with Doppler-detected FCR, the site of the leak was correctly identified by observing the location of the FCR. A trivial jet area was detected in eight patients with a normally functioning mitral prosthesis; in none was an FCR identified. Thus color Doppler visualization of the FCR proximal to the regurgitant orifice is superior to the jet area in the diagnosis of mechanical prosthetic mitral regurgitation. Moreover, FCR permits localization of the site of the leak with good accuracy.
Authors:
G S Bargiggia; L Tronconi; A Raisaro; F Recusani; T Ragni; L M Valdes-Cruz; D J Sahn; C Montemartini
Related Documents :
9591766 - Mitral regurgitation: impaired systolic function, eccentric hypertrophy, and increased ...
11053696 - Prognostic significance of mild mitral regurgitation by color doppler echocardiography ...
24432186 - Coronary-cameral fistulas in adults: acquired types (second of two parts).
9631266 - Evaluation of hemolysis in patients with prosthetic heart valves.
16412806 - Effect of estradiol 17beta upon coronary artery vasoconstrictor response to methylergom...
20200636 - Use of an active-fixation coronary sinus lead to implant a biventricular pacemaker via ...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  American heart journal     Volume:  120     ISSN:  0002-8703     ISO Abbreviation:  Am. Heart J.     Publication Date:  1990 Nov 
Date Detail:
Created Date:  1990-12-04     Completed Date:  1990-12-04     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0370465     Medline TA:  Am Heart J     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1137-42     Citation Subset:  AIM; IM    
Affiliation:
IRCCS Policlinico S. Matteo, Division of Cardiology, Pavia, Italy.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Echocardiography, Doppler*
Female
Heart Valve Prosthesis*
Humans
Male
Middle Aged
Mitral Valve
Prosthesis Failure

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Are ioxaglate and iopamidol equally safe and well tolerated in cardiac angiography? A randomized, do...
Next Document:  Transesophageal echocardiography in the awake elderly patient: its role in the clinical decision-mak...