Document Detail

Coil embolization of inferior epigastric artery pseudoaneurysm after percutaneous thrombin injection failure: a case report.
Jump to Full Text
MedLine Citation:
PMID:  19918533     Owner:  NLM     Status:  PubMed-not-MEDLINE    
Abstract/OtherAbstract:
We report a case of a 71-year old woman with right inferior epigastric artery pseudoaneurysm following laceration by a computed tomography-guided 18G biopsy needle. The laceration was initially treated with placement of retained sutures; however the patient turned hemodynamically unstable 41 days later. Percutaneous ultrasound-guided injection of 1500 U of thrombin solution resulted in almost complete thrombosis of the pseudoaneurysm; however 24 hour control ultrasound revealed refilling of the pseudoaneurysm. Definite treatment was achieved by transcatheter coil embolization. Inferior epigastric artery pseudoaneurysm with underlying laceration may not respond to percutaneous thrombin injection, whereas coil embolization is shown to be effective.
Authors:
Miltiadis Krokidis; Adam Hatzidakis; John Petrakis; Theodoros Lagoudis; Dimitrios Tsetis
Related Documents :
15877253 - A false aneurysm mistaken for a dvt after hip surgery.
12828093 - Totally implantable arterial device (tiad): a questionable complication.
25177953 - A study of microemboli monitoring of atherosclerotic thrombotic cerebral infarction and...
Publication Detail:
Type:  Journal Article     Date:  2009-08-12
Journal Detail:
Title:  Cases journal     Volume:  2     ISSN:  1757-1626     ISO Abbreviation:  Cases J     Publication Date:  2009  
Date Detail:
Created Date:  2009-11-17     Completed Date:  2011-01-07     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101474272     Medline TA:  Cases J     Country:  England    
Other Details:
Languages:  eng     Pagination:  6562     Citation Subset:  -    
Affiliation:
Department of Radiology, University Hospital of Heraklion, Medical School of Crete, Heraklion, Greece. mkrokidis@hotmail.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): Cases J
ISSN: 1757-1626
Publisher: Cases Network Ltd
Article Information
? 2009 Krokidis et al.; licensee Cases Network Ltd.
open-access:
Received Day: 14 Month: 3 Year: 2009
Accepted Day: 25 Month: 6 Year: 2009
Electronic publication date: Day: 12 Month: 8 Year: 2009
collection publication date: Year: 2009
Volume: 2E-location ID: 6562
PubMed Id: 19918533
DOI: 10.4076/1757-1626-2-6562
Publisher Id: 6562

Coil embolization of inferior epigastric artery pseudoaneurysm after percutaneous thrombin injection failure: a case report
Miltiadis Krokidis1 Email: mkrokidis@hotmail.com
Adam Hatzidakis1 Email: adamhatz@med.uoc.gr
John Petrakis2 Email: Tlagoud@yahoo.gr
Theodoros Lagoudis2 Email: Jpetrak@med.uoc.gr
Dimitrios Tsetis1 Email: tsetis@med.uoc.gr
1Department of Radiology, University Hospital of Heraklion, Medical School of CreteHeraklionGreece
2Department of General Surgery, University Hospital of Heraklion, Medical School of CreteHeraklionGreece

Introduction

Due to its anatomic location, inferior epigastric artery (IEA) laceration and pseudoaneurysm formation is a potential complication of removal of surgical retention sutures [1], paracentesis [2], catheter removal [3], drain placement [4] or percutaneous biopsy of abdominal masses [5]. Reported treatment choices include surgical repair [3,5], percutaneous techniques [1,2,4,6-8] or combination of both [9].

We report a case of iatrogenic pseudoaneurysm of the IEA which occurred 41 days after CT-guided biopsy of a mass lying under the abdominal wall and surgical tamponag? of lacerated IEA. Percutaneous thrombin injection failed to control the pseudoaneurysm and this was successfully embolized with coils. The efficacy of percutaneous thrombin injection for the treatment of iatrogenic pseudoaneurysms has been widely documented [8,10,11]. However only few reports exist on thrombin failure and to our knowledge this is the first reported case of thrombin failure in an iatrogenic IEA aneurysm treated definitely with coil embolization.


Case presentation

A 71-year old Greek female patient with a history of surgical resection of gastrointestinal stromal tumor (GIST) from the jejunum 21 months ago, presented with a CT follow-up diagnosis of a mass in the right inferior abdominal quadrant in contiguity with the abdominal wall and the uterus fundus. In order to exclude recurrence, a CT-guided biopsy was decided. The biopsy was performed under local anesthesia with an 18G semi-automatic biopsy gun (Figure 1a). Immediately after the second puncture the patient became hemodynamically unstable and control scan revealed active hemorrhage within the mass (Figure 1b). The patient was immediately transferred to the operating theatre where surgical tamponnage with retention sutures around the punctured region was performed. She turned hemodynamically stable 7 days later and remained in the Intensive Care Unit for 21 days. The patient spent another 20 days in the General Surgery department for complete recovery. Forty-one days after the biopsy the patient suddenly became hemodynamically unstable again. She was transferred to the Interventional Radiology suite, where an US Doppler examination revealed the presence of a 5.5 ? 3.9 cm pseudoaneurysm in the punctured region with a neck width of 0.58 cm (Figure 2). As this was considered as the cause of the hematocrit drop, treatment with percutaneous thrombin injection was decided. After local anesthesia a 21G needle was advanced under US-guidance and its tip was positioned in the middle of the pseudoaneurysm cavity away from the neck (Figure 3a). A solution of 1000 U/ml bovine-derived Thrombin Component (FloSeal, Baxter Healthcare, Fremont, CA, USA) was injected slowly at a rate of 0.1 ml/sec. The thrombotic process was controlled intermittently (in every 0.5 ml aliquots of the solution) with color Doppler. After a total amount of 1.5 ml of thrombin solution, almost complete pseudoaneurysm thrombosis was achieved (Figure 3b). No further thrombin injection was performed due to the patient?s hemodynamic instability. The patient?s hematocrit increased in the next six hours and she turned stable 12 hours later. The next day the patient complained of pain and hematocrit dropped again. An US examination revealed partial refilling of the pseudoaneurysm. Percutaneous embolization of the pseudoaneurysm was decided. Selective angiography of the internal iliac artery confirmed the presence of an IEA pseudoaneurysm (Figure 4). Superselective catheterization of the IEA with a 3Fr microcatheter (SP, Terumo Europe) and subsequent embolization with 5 mm metallic coils (Cook, Denmark) was performed successfully. The coils were deployed proximal and distal to the pseudoaneurysm neck, in order to stop blood supply through the superior and the inferior epigastric branches (Figure 5). The patient turned definitively stable and was released one week later. In the follow-up visit 6 months later no pseudoaneurysm recurrence was noted on US.


Discussion

Inferior epigastric artery is a vessel keen to iatrogenic laceration after various medical procedures due to its superficial route. In the majority of cases a pseudoaneurysm is formed, the patient remaining stable. However, in one case of IEA laceration after percutaneous biopsy a large haematoma was formed, surgical control failed and patient died [5].

Surgical ligation of the lacerated vessel was not attempted in our case due to obscuration of the vessel by a large haematoma and therefore retention sutures were placed around the lacerated lesion. In a similar case reported by Todd et al after laparotomy, surgical access to the haematoma allowed direct ligation of the vessel. However the patient turned unstable and the patient died 36 hrs later [5]. We believe that the IEA pseudoaneurysm formation 41 days after the biopsy was probably due to the gradual absorbance of the formed haematoma or of one of the retention sutures which resulted in relaxation of the tamponating forces on the lacerated vessel.

Patients with IEA pseudoaneurysms may be hemodynamically stable or unstable, depending on the tamponating force that the extravasating blood receives from the surrounding tissues [1-4,10].

Treatment options of IEA pseudoaneurysms include surgical ligation of the lacerated vessel [3], transcatheter embolization [2,4,6], percutaneous thrombin injection [10] or direct compression [1].

Percutaneous thrombin injection is a widely accepted method for the treatment of pseudoaneurysms of the common femoral artery (CFA) that usually occurs after catheterization for interventional procedures [7]. There is only one case in the literature of a spontaneous IEA pseudoaneurysm which was treated successfully with percutaneous thrombin injection [8]. We decided to apply this type of therapy in our patient due to her debilitating condition.

Thrombin failure has been reported in the literature. Sheiman et al, in a study of 54 patients with simple CFA iatrogenic pseudoaneurysms treated with percutaneous US-guided thrombin injection concluded that their failure rate of 9% was due to an underlying sonographically occult vascular injury due to vessel laceration or infection. They also speculated that need for a dose more than 1000U of thrombin for pseudoaneurysm thrombosis is an indirect indicator of a large arteriotomy site defect requiring closer clinical follow-up [12].

In the reported case of IEA pseudoaneurysm that was treated with percutaneous thrombin injection, Shabani et al. refer a rare case of spontaneous pseudoaneurysm [8]. The authors do not refer previous traumatic mechanism or shear forces; therefore we may presume that the IEA has not been previously seriously lacerated. In our case 1500 U of thrombin were given but treatment failed for unknown reasons. A possible explanation may be that damaged endothelium at sites of a large arteriotomy or laceration expresses thrombomodulin which complexes with thrombin to activate protein C. Activated protein C is known to activate an anticoagulation pathway [13] and reduce the relative size and number of fibrin fibers within maturing thrombus [14]. This mechanism may help to explain why the clot which developed within the unsuccessfully treated pseudoaneurysm underwent spontaneous thrombolysis within 24 hrs leading to pseudoaneurysm recurrence.

Percutaneous coil embolization has shown to be effective in the hemorrhage control in all the reported cases [2,4,6]. In all cases the proximal and distal portions of the feeding vessel has been embolized with coils and complete thrombosis of the pseudoaneurysm has been achieved. Ferer et al, recommend surgical treatment for the cases of large pseudoaneurysms and percutaneous embolization for smaller lesions [15]. In a more recent study Lam et al, reported two cases of large pseudoaneurysms that have been successfully embolized [2].

We attempted initially the thrombin approach due to the fact it is a simple, quick and safe technique, minimally invasive, painless and very effective. We believe that the significant vessel wall laceration was the cause of the thrombin failure. Nevertheless, the patient was successfully treated with percutaneous embolization which is a more invasive, established intravascular therapeutic approach. We suggest this approach sequence as the most appropriate in the cases of IEA pseudoaneurysms.


Notes
Consent

Written informed consent was obtained from the patient for publication of this case report and accompanying images. A copy of the written consent is available for review by the journal?s Editor-in-Chief.

Competing interests

The authors declare that they have no competing interests.

Authors? contribution

MK, AH, JP, TL, and DT involved in scientific context and editing. All authors read and approved the final manuscript.


References
Takase K,Kazama T,Abe K,Chiba Y,Saito H,Takahashi S. Pseudoaneurysm of the inferior epigastric artery successfully treated by ultrasound-guided compressionCardiovasc Intervent RadiolYear: 2004275205221538385910.1007/s00270-003-2767-x
Lam EY,McLafferty RB,Taylor LM Jr,Moneta GL,Edwards JM,Barton RE,Petersen B,Porter JM. Inferior epigastric artery pseudoaneurysm: a complication of paracentesisJ Vasc SurgYear: 199828566569973747110.1016/S0741-5214(98)70147-8
Werner M,Bernheim J,Witz M,Gritton Y,Savin H,Korzets Z. Pseudoaneurysm of the inferior epigastric artery-a rare complication of Tenckhoff catheter removalNephrol Dial TransplantYear: 1999145129712991034438610.1093/ndt/14.5.1297
Pinero A,Reus M,Agea B,Capel A,Riquelme J,Parrilla P. Conservative management of an arteriovenous fistula of the inferior epigastric arteryBr J RadiolYear: 2003769021351361264228410.1259/bjr/87038703
Todd AW. Inadvertent puncture of the inferior epigastric artery during needle biopsy with fatal outcomeClin RadiolYear: 200156129899901179592910.1053/crad.2001.0175
Gage SG,Sussman SK,Conrad FU,Hull D,Bartus SA. Pseudoaneurysm of the inferior epigastric artery: diagnosis and percutaneous treatmentAJRYear: 19901555295302143622
Bennett JD. Evidence-based radiology problems. Inferior epigastric artery pseudoaneurysm: computed tomographic diagnosis and transcatheter therapyCan Assoc Radiol JYear: 200455181114999862
Shabani AG,Baxter GM. Inferior epigastric artery pseudoaneurysm: ultrasound diagnosis and treatment with percutaneous thrombinBr J RadiolYear: 20027589668969112153944
Georgiadis GS,Souftas VD,Papas TT,Lazarides MK,Prassopoulos P. Inferior epigastric artery false aneurysms: review of the literature and case reportEur J Vasc Endovasc SurgYear: 2007331821861705575510.1016/j.ejvs.2006.08.006
Friedman SG,Pellerito JS,Scher L,Faust G,Burke B,Safa T. Ultrasound-guided thrombin injection is the treatment of choice for femoral pseudoaneurysmsArch SurgYear: 20021374624641192695410.1001/archsurg.137.4.462
Kruger K,Zaehringer M,Strohe D,Stuetzer H,Boecker J,Lackner K. Postcatheterization pseudoaneurysm: results of us-guided percutaneous thrombin injection in 240 patientsRadiologyYear: 2005236110411101605569410.1148/radiol.2363040736
Sheiman R,Mastromatteo M. Iatrogenic femoral pseudoaneurysms that are unresponsive to percutaneous thrombin injection: potential causesAJRYear: 20031811301130314573423
Sadler JE. Thrombomodulin structure and functionThromb HaemostYear: 1997783923959198185
Gruber A,Mori E,del Zoppo GI,Waxman L,Griffin JH. Alteration of fibrin network by activated proteinBloodYear: 199483254125488167339
Ferrer JV,Soriano P,Zazpe C,Vicente F,Herrera J,Lera JM. Pseudoaneurysm of the inferior epigastric artery. Pathogenesis, diagnosis, and treatmentArch SurgYear: 199613111021038546568

Abbreviations
CFA common femoral artery
CT computed tomography
GIST gastrointestinal stromal tumors
IEA inferior epigastric artery

Figures

[Figure ID: fig-001]
Figure 1. 

(a) Biopsy of a mass in the right inferior abdominal quadrant with an 18G Semi-automatic biopsy gun (arrow) (b) Hyperdense area (arrow) indicating active hemorrhage within the mass following 2nd biopsy puncture.



[Figure ID: fig-002]
Figure 2. 

The 5.5 ? 3.9 cm pseudoaneurysm 41 days after biopsy.



[Figure ID: fig-003]
Figure 3. 

(a) Echogenic tip of the 21 G needle in the middle of the pseudoaneurysm cavity. (b) Almost complete thrombosis of the pseudoaneurysm after injection of 1500 U (1, 5 ml) of thrombin into the pseudoaneurysm sac.



[Figure ID: fig-004]
Figure 4. 

Selective angiography of the EIA demonstrates IEA pseudoaneurysm (arrow).



[Figure ID: fig-005]
Figure 5. 

Successful embolization with metallic coils proximal and distal to the pseudoaneurysm neck.



Article Categories:
  • Case report


Previous Document:  Acute fulminant necrotizing amoebic colitis: a rare and fatal complication of amoebiasis: a case rep...
Next Document:  Traumatic diaphragmatic rupture, a diagnostic dilemma in the presence of eventration: a case report.