Document Detail


Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.
MedLine Citation:
PMID:  23300043     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
OBJECTIVE: To perform preliminary tests in vitro and with healthy volunteers to determine the 3-T MRI compatibility of a cochlear implant with a non-removable magnet. METHODS: In the in vitro phase, we tested six implants for temperature changes and internal malfunctioning. We measured the demagnetisation of 65 internal magnets with different tilt angles between the implant's magnetic field (bi) and the main magnetic field (b0). In the in vivo phase, we tested 28 operational implants attached to the scalps of volunteers with the head in three different positions. RESULTS: The study did not find significant temperature changes or electronic malfunction in the implants tested in vitro. We found considerable demagnetisation of the cochlear implant magnets in the in vitro and in vivo testing influenced by the position of the magnet in the main magnetic field. We found that if the bi/b0 angle is <90°, there is no demagnetisation; if the bi/b0 angle is >90°, there is demagnetisation in almost 60 % of the cases. When the angle is around 90°, the risk of demagnetisation is low (6.6 %). CONCLUSION: The preliminary results on cochlear implants with non-removable magnets indicate the need to maintain the contraindication of passage through 3-T MRI. KEY POINTS : • Magnetic resonance imaging can affect cochlear implants and vice versa. • Demagnetisation of cochlear implant correlates with the angle between bi and b0. • The position of the head in the MRI influences the demagnetisation. • Three-Tesla MRI for cochlear implants is still contraindicated. • However some future solutions are discussed.
Authors:
F Dubrulle; A Sufana Iancu; C Vincent; G Tourrel; O Ernst
Related Documents :
21691513 - Maxillary canine with two root canals.
1556253 - Reduction of papilloma size by ultraviolet irradiation in the japanese newt, cynops pyr...
18531823 - Nondestructive evaluation of heterogeneous materials using acoustic emission and ultras...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-1-10
Journal Detail:
Title:  European radiology     Volume:  -     ISSN:  1432-1084     ISO Abbreviation:  Eur Radiol     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-1-9     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9114774     Medline TA:  Eur Radiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Radiology, CHU Lille, Huriez Hospital, 1 rue Polonovski, 59037, Lille cedex, France, F-DUBRULLE@chru-lille.fr.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A decision tree for differentiating multiple system atrophy from Parkinson's disease using 3-T MR im...
Next Document:  Can Black-and-White Ruffed Lemurs (Varecia variegata) Solve Object Permanence Tasks?