Clinically significant magnetic interference of implanted cardiac devices by portable headphones.
MedLine Citation:
PMID:  19968922     Owner:  NLM     Status:  In-Process    
Abstract/OtherAbstract:
BACKGROUND: Little is known about the magnetic field strength of portable headphones and their potential to cause magnetic interference with implanted pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs). OBJECTIVE: The purpose of this study was to evaluate the magnetic field strength of portable headphones and to determine if they can cause clinically relevant magnetic interference. METHODS: PM or ICD function was assessed in 100 patients during exposure to eight different models of portable headphones to determine the incidence of clinically relevant magnetic interference. The magnetic field strength of the headphones also was measured in vitro. RESULTS: Clinically relevant magnetic interference from portable headphones occurred in 30 (30%) of 100 patients and more commonly affected ICD than PM patients (21/55 [38.2%] vs 9/45 [20.0%]; P = .048). All patients affected by magnetic interference experienced a magnet response, characterized by asynchronous pacing in PM patients and by inhibition of tachyarrhythmia detection in ICD patients. In all but one of the 30 cases of magnetic interference, removal of the headphones from the patient's chest immediately restored normal device function. Headphones with a measured magnetic field strength > or =10 gauss at 2 cm were much more likely to cause magnetic interference than were those with lower magnetic field strength (30/100 [30%] patients vs 0/100 [0%] patients; P <.0001). Magnetic interference was not observed when headphones were placed > or =3 cm from the skin surface. CONCLUSION: Clinically significant magnetic interference can occur when portable headphones are placed in close proximity to implanted PMs and ICDs. Patients with such a device should be advised to keep portable headphones at least 3 cm from their device.
Authors:
Sinjin Lee; Kevin Fu; Tadayoshi Kohno; Benjamin Ransford; William H Maisel
Publication Detail:
Type:  Journal Article     Date:  2009-07-08
Journal Detail:
Title:  Heart rhythm : the official journal of the Heart Rhythm Society     Volume:  6     ISSN:  1556-3871     ISO Abbreviation:  Heart Rhythm     Publication Date:  2009 Oct 
Date Detail:
Created Date:  2009-12-08     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101200317     Medline TA:  Heart Rhythm     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1432-6     Citation Subset:  IM    
Affiliation:
Cardiovascular Institute, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA 02215, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Comments/Corrections
Comment In:
Heart Rhythm. 2009 Oct;6(10):1437-8   [PMID:  19716347]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Radiofrequency ablation of atrial fibrillation under therapeutic international normalized ratio: A s...
Next Document:  The cardiac veins in congenitally corrected transposition of the great arteries: Delivery options fo...