Clinical experience with the Diametrics IRMA (Immediate Response Mobile Analysis) blood analysis system.
MedLine Citation:
PMID:  9131718     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The Immediate Response Mobile Analysis (IRMA) blood analysis system (Diametrics Medical Incorporated, St Paul, MN, USA) is a new point-of-care testing device that uses technology similar to the Gem Premier (Mallinckrodt Sensor Systems Incorporated, Ann-Arbor, MI, USA), which are ion-specific electrodes. We compared these two analysers using both patient blood samples (n = 50) and aqueous quality control solutions (n = 45). Linear regression (Pearson product-moment correlation coefficient) was performed to quantify the strength of the association between results. In addition, bias and precision were determined in accordance with the method described by Bland and Altman. The results demonstrated excellent correlation between the IRMA and the Gem Premier, and bias and precision were acceptable for both patient and quality control samples. Reproducibility of results was also assessed using one level of aqueous quality control solution (n = 50). The IRMA demonstrated very little variance in parameter readings over a five-day study period.
Authors:
K D Hedlund; S Oen; L LaFauce; D M Sanford
Related Documents :
8037158 - Use of lyophilized calibration plasmas and control blood for international normalized r...
11859268 - A prolonged time interval between blood sample collection and centrifugation causes an ...
19569328 - Geographical distribution of perfluorinated compounds in human blood from liaoning prov...
12742708 - Rapid determination of carboxyhemoglobin in blood by oximeter.
356788 - The care of vascular endothelium in pediatric surgery.
12209238 - Minimal blood loss in patients undergoing radical retropubic prostatectomy.
Publication Detail:
Type:  Clinical Trial; Comparative Study; Journal Article    
Journal Detail:
Title:  Perfusion     Volume:  12     ISSN:  0267-6591     ISO Abbreviation:  Perfusion     Publication Date:  1997 Mar 
Date Detail:
Created Date:  1997-07-03     Completed Date:  1997-07-03     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8700166     Medline TA:  Perfusion     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  27-30     Citation Subset:  IM    
Affiliation:
St Francis Hospital and Medical Center, Topeka, Kansas 66606-1690, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Blood
Blood Chemical Analysis / instrumentation*,  methods*
Humans
Point-of-Care Systems*
Quality Control
Regression Analysis
Reproducibility of Results
Solutions
Chemical
Reg. No./Substance:
0/Solutions

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Effects of heparin coating on the expression of CD11b, CD11c and CD62L by leucocytes in extracorpore...
Next Document:  Side effects of nondepolarizing muscle relaxants: relationship to their antinicotinic and antimuscar...