Clinical assessment of blood pressure.
MedLine Citation:
PMID:  2096205     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
This study was performed to determine the blood pressure measuring techniques and accuracy of sphygmomanometers used by physicians in ambulatory care clinics on the Avalon Peninsula of Newfoundland. Of the 114 participating physicians, no physician completely followed all the recommended BP measuring techniques of the American Heart Association. Almost all physicians supported the patient's arm at heart level to measure BP. Fewer physicians used the following recommended techniques; palpation to initially assess systolic BP (38%), measurement of BP in both arms (23%), an appropriate rate of cuff deflation (18%), measurement of BP in recommended patient positions (10%), the appropriate length of rest (4%) or use of a cuff of appropriate size (3%). Approximately 8% of mercury sphygmomanometers were out of calibration by at least 4 mmHg but none were out by more than 6 mmHg. Forty percent of aneroid sphygmomanometers were out of calibration by at least 4 mmHg and of these 30% were out by 10 mmHg or more. Mercury and aneroid sphygmomanometers were used by 60% of physicians. Aneroid sphygmomanometers were used exclusively by 34% of physicians, while 5% of physicians relied solely on mercury devices. Standardized techniques for BP measurement are not used and inaccurate sphygmomanometers are common; these factors may lead to misclassification of blood pressure and inappropriate treatment of patients.
Authors:
D W McKay; N R Campbell; L S Parab; A Chockalingam; J G Fodor
Related Documents :
3453385 - Clinical validation of the accutracker, a novel ambulatory blood pressure monitor using...
8500385 - Comparison of blood pressure measurement methods in critically ill children.
998175 - Changes in cardiac function during and after pregnancy expressed by systolic time inter...
25278775 - Optimal perioperative management of arterial blood pressure.
16431555 - Arterial pressures in a general practice.
2004925 - Differential effects of continuous versus intermittent suction on tracheal tissue.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Journal of human hypertension     Volume:  4     ISSN:  0950-9240     ISO Abbreviation:  J Hum Hypertens     Publication Date:  1990 Dec 
Date Detail:
Created Date:  1991-07-17     Completed Date:  1991-07-17     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8811625     Medline TA:  J Hum Hypertens     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  639-45     Citation Subset:  IM    
Affiliation:
Division of Basic Medical Sciences, Faculty of Medicine, Memorial University of Newfoundland, St John's, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Blood Pressure* / physiology
Blood Pressure Determination / instrumentation,  methods*
Calibration / standards
Humans
Hypertension / diagnosis

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Placebo effect and adaptation to noninvasive monitoring of BP.
Next Document:  The relative accuracy of simultaneous same arm, simultaneous opposite arm and sequential same arm me...