Document Detail


Chromic gut pelviscopic loop ligature. Effect of the number of pulls on the tensile strength.
MedLine Citation:
PMID:  2325039     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The failure load of a pelviscopic loop ligature (PLL) was determined after tightening the slip knot with one, two or three pulls. The PLL showed a significant decrease in strength when tightened with three or more pulls. In each group some PLLs failed from slippage rather than from fracture of the suture material at the base of the knot. Slippage occurred more frequently with each additional pull. The findings indicate that the surgeon should apply only one pull on the device for the most secure knot. In addition, there was no strength difference between the suture material itself and the junction of the suture and its plastic tail grip. The plastic tail grip of the PLL will not release the tail end of the suture material before either the suture material or the slip knot fails.
Authors:
D L Hay; R L Levine; J A von Fraunhofer; B J Masterson
Related Documents :
1850429 - Ultra-high-strength absorbable self-reinforced polyglycolide (sr-pga) composite rods fo...
2269789 - Double loop locking suture: a technique of tendon repair for early active mobilization....
9697809 - Pubic symphysis repair strength in simulated bladder exstrophy using a sheep model.
1569879 - Slip-knot suspension technique: a fail-safe microanastomosis for small-caliber vessels.
19524229 - Fiberwire is superior in strength to stainless steel wire for tension band fixation of ...
18216689 - Confocal laser scanning microscopic analysis of collagen scaffolding patterns in crania...
8014549 - Migration of silicone rods.
1471519 - Perioperative factors associated with septic arthritis after arthroplasty. prospective ...
22891099 - Superior dislocation hip with anterior column acetabular fracture - open reduction and ...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  The Journal of reproductive medicine     Volume:  35     ISSN:  0024-7758     ISO Abbreviation:  J Reprod Med     Publication Date:  1990 Mar 
Date Detail:
Created Date:  1990-05-16     Completed Date:  1990-05-16     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0173343     Medline TA:  J Reprod Med     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  260-2     Citation Subset:  IM    
Affiliation:
Department of Obstetrics and Gynecology, Good Samaritan Hospital, Cincinnati, Ohio.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Catgut*
Ligation / instrumentation
Sutures*
Tensile Strength