Document Detail


Characterization of an air jet haptic lump display.
MedLine Citation:
PMID:  22255086     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
During manual palpation, clinicians rely on distributed tactile information to identify and localize hard lumps embedded in soft tissue. The development of tactile feedback systems to enhance palpation using robot-assisted minimally invasive surgery (RMIS) systems is challenging due to size and weight constraints, motivating a pneumatic actuation strategy. Recently, an air jet approach has been proposed for generating a lump percept. We use this technique to direct a thin stream of air through an aperture directly on the finger pad, which indents the skin in a hemispherical manner, producing a compelling lump percept. We hypothesize that the perceived parameters of the lump (e.g. size and stiffness) can be controlled by jointly adjusting air pressure and the aperture size through which air escapes. In this work, we investigate how these control variables interact to affect perceived pressure on the finger pad. First, we used a capacitive tactile sensor array to measure the effect of aperture size on output pressure, and found that peak output pressure increases with aperture size. Second, we performed a psychophysical experiment for each aperture size to determine the just noticeable difference (JND) of air pressure on the finger pad. Subject-averaged pressure JND values ranged from 19.4-24.7 kPa, with no statistical differences observed between aperture sizes. The aperture-pressure relationship and the pressure JND values will be fundamental for future display control.
Authors:
Matteo Bianchi; James C Gwilliam; Alperen Degirmenci; Allison M Okamura
Related Documents :
18627236 - Effect of intranasal oxygen administration on blood gas variables and outcome in neonat...
20561856 - Comparison of effects of manual versus ventilator hyperinflation on respiratory complia...
3103366 - Continuous monitoring of oxygen tension with a transcutaneous sensor during hypotensive...
21568416 - Distribution of standing-wave errors in real-ear sound-level measurements.
18534276 - Hemodynamic, echocardiographic, and neurohormonal effects of istaroxime, a novel intrav...
22060196 - Levels of calpain and calpastatin in meat subjected to high pressure.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, Non-P.H.S.    
Journal Detail:
Title:  Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference     Volume:  2011     ISSN:  1557-170X     ISO Abbreviation:  Conf Proc IEEE Eng Med Biol Soc     Publication Date:  2011  
Date Detail:
Created Date:  2012-01-18     Completed Date:  2012-06-20     Revised Date:  2014-08-21    
Medline Journal Info:
Nlm Unique ID:  101243413     Medline TA:  Conf Proc IEEE Eng Med Biol Soc     Country:  United States    
Other Details:
Languages:  eng     Pagination:  3467-70     Citation Subset:  IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Air*
Humans
Psychophysics
Robotics
Skin / anatomy & histology*
Touch

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Development of a spatially transparent electrotactile display and its performance in grip force cont...
Next Document:  Redundancy resolution of a human arm for controlling a seven DOF wearable robotic system.