Changes in intraocular pressure after laser in situ keratomileusis.
MedLine Citation:
PMID:  11471999     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE: To evaluate changes in intraocular pressure (IOP) measurements by Goldmann applanation tonometry after laser in situ keratomileusis (LASIK) for myopia and myopic astigmatism, and to assess the accuracy of Goldmann applanation tonometry measurements after LASIK in these eyes. METHODS: LASIK was performed on 166 eyes of 93 patients for correction of myopia and myopic astigmatism. Intraocular pressure was measured by Goldmann applanation tonometry at the central and temporal parts of the cornea before and at 1, 3, 6, and 12 months after LASIK. The amount of change in IOP was computed and its relation to different variables was evaluated by regression analysis. RESULTS: Intraocular pressure measured at the center of the cornea was reduced by a mean of 3.69 +/- 1.63 mmHg after LASIK. Multiple regression analysis showed that the decrease in IOP was related to the preoperative IOP and the change in central corneal thickness after LASIK. Measurements of IOP at the temporal part of the cornea were also reduced by a mean of 2.39 +/- 1.71 mmHg. There was wide variability in the amount of difference between the temporal and central measurements after LASIK (temporal measurements were higher than central by 0 to +4 mmHg). CONCLUSION: LASIK for myopia produced underestimation of IOP measured by Goldmann applanation tonometry at the central part of the cornea by a mean of 3.69 +/- 1.63 mmHg. The decrease of IOP was related to preoperative IOP and the change in central corneal thickness after LASIK. Temporal Goldmann applanation tonometry measurements, although decreased after LASIK, were less reliable.
Authors:
K M Rashad; A A Bahnassy
Related Documents :
16497239 - Effects of systemic administration of 0.5% tropicamide on intraocular pressure, pupilla...
18801579 - The accuracy of continued clinical use of goldmann applanation tonometers with known ca...
11006239 - Retrograde axonal transport of bdnf in retinal ganglion cells is blocked by acute iop e...
18435659 - Effects of nitrous oxide on iop and pupillary diameter in dogs anesthetized with varyin...
7387959 - Timolol in operated closed-angle glaucoma.
11558809 - A randomized trial of the long-term effects of digital ocular compression in the late p...
6460889 - The hypotensive mechanisms of the new anti-anginal drug, n-(2-hydroxyethyl)nicotinamide...
3453169 - Systolic blood pressure as an independent predictor of mortality in the hypertension de...
20057199 - Cardiorespiratory fitness and components of the metabolic syndrome in sedentary men.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of refractive surgery (Thorofare, N.J. : 1995)     Volume:  17     ISSN:  1081-597X     ISO Abbreviation:  J Refract Surg     Publication Date:    2001 Jul-Aug
Date Detail:
Created Date:  2001-07-26     Completed Date:  2001-12-04     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  9505927     Medline TA:  J Refract Surg     Country:  United States    
Other Details:
Languages:  eng     Pagination:  420-7     Citation Subset:  IM    
Affiliation:
Ophthalmology Department, Faculty of Medicine, Alexandria University, Egypt.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Astigmatism / surgery*
Cornea / anatomy & histology,  physiology*,  surgery
Female
Humans
Intraocular Pressure / physiology*
Keratomileusis, Laser In Situ*
Male
Middle Aged
Myopia / surgery*
Reproducibility of Results
Tonometry, Ocular / standards

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Schematic eye models for simulation of patient visual performance.
Next Document:  Morphology of the stromal surface and endothelium using two different microkeratomes.