Document Detail


Central venous pulse pressure analysis using an R-synchronized pressure measurement system.
MedLine Citation:
PMID:  17053869     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: The information derived from central venous catheters is underused. We developed an EKG-R synchronization and averaging system to obtained distinct CVP waveforms and analyzed components of these. METHODS: Twenty-five paralyzed surgical patients undergoing CVP monitoring under mechanical ventilation were studied. CVP and EKG signals were analyzed employing our system, the mean CVP and CVP at end-diastole during expiration were compared, and CVP waveform components were measured using this system. RESULTS: CVP waveforms were clearly visualized in all patients. They showed the a peak to be 1.8+/- 0.7 mmHg, which was the highest of three peaks, and the x trough to be lower than the y trough (-1.6+/- 0.7 mmHg and -0.9+/- 0.5 mmHg, respectively), with a mean pulse pressure of 3.4 mmHg. The difference between the mean CVP and CVP at end-diastole during expiration was 0.58+/- 0.81 mmHg. CONCLUSIONS: The mean CVP can be used as an index of right ventricular preload in patients under mechanical ventilation with regular sinus rhythm. Our newly developed system is useful for clinical monitoring and for education in circulatory physiology.
Authors:
Yoshihisa Fujita; Daisuke Hayashi; Shinya Wada; Naoki Yoshioka; Takeshi Yasukawa; Gunther Pestel
Related Documents :
9591529 - Effect of felodipine on arterial blood flow and venous function at rest in patients wit...
8174539 - Cardiovascular and cerebrovascular effects of the applied valsalva manoeuvre in anaesth...
18372699 - Effect of the elastic compression stockings on the calf veins and tissues during a simu...
11263609 - Preservation of venous endothelial function in the forearm venous capacitance bed of pa...
3970419 - Venous blood pressure relative to the development of bovine udder edema.
1741229 - Accuracy of central venous pressure measurement from the abdominal inferior vena cava.
7509259 - Effects of a nitric oxide synthase inhibitor in humans with septic shock.
15364849 - Importance of mitral valve second-order chordae for left ventricular geometry, wall thi...
864419 - Elevated blood pressure in the young adult.
Publication Detail:
Type:  Evaluation Studies; Journal Article     Date:  2006-10-20
Journal Detail:
Title:  Journal of clinical monitoring and computing     Volume:  20     ISSN:  1387-1307     ISO Abbreviation:  J Clin Monit Comput     Publication Date:  2006 Dec 
Date Detail:
Created Date:  2006-12-04     Completed Date:  2007-08-15     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9806357     Medline TA:  J Clin Monit Comput     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  385-9     Citation Subset:  IM    
Affiliation:
Department of Anesthesiology & ICM, Kawasaki Medical School, 577 Matsushima, Kurashiki-city, Okayama, 701-0192, Japan. fujitay@med.kawasaki-m.ac.jp
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Blood Pressure Determination / methods*,  statistics & numerical data
Central Venous Pressure*
Electrocardiography / statistics & numerical data
Humans
Monitoring, Physiologic / methods*,  statistics & numerical data

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Fibrin glue as an adjunct to flap repair of anal fistulas: a randomized, controlled study.
Next Document:  Depressive symptoms as a risk factor for osteoporosis and fractures in older Mexican American women.