Document Detail


Central venous pressure: A useful but not so simple measurement.
MedLine Citation:
PMID:  16763509     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: To review the clinical use of central venous pressure measurements. DATA SOURCES: The Medline database, biographies of selected articles, and the author's personal database. DATA SYNTHESIS: Four basic principles must be considered. Pressure measurements with fluid-filled systems are made relative to an arbitrary reference point. The pressure that is important for preload of the heart is the transmural pressure, whereas the pressure relative to atmosphere still affects other vascular beds outside the thorax. The central venous pressure is dependent upon the interaction of cardiac function and return function. There is a plateau to the cardiac function curve, and once it is reached, further volume loading will not increase cardiac output. CONCLUSIONS: If careful attention is paid to proper measurement techniques, central venous pressure can be very useful clinically. However, the physiologic or pathophysiological significance of the central venous pressure should be considered only with a corresponding measurement of cardiac output or at least a surrogate measure of cardiac output.
Authors:
Sheldon Magder
Related Documents :
15517159 - Effects of continuous negative extra-abdominal pressure on cardiorespiratory function d...
11834669 - Central venous and bladder pressure reflect transdiaphragmatic pressure during pressure...
16179049 - Accuracy of central venous pressure monitoring during simultaneous continuous infusion ...
20884839 - Adrenergic mechanisms do not contribute to age-related decreases in calf venous complia...
19707129 - Association of physical examination with pulmonary artery catheter parameters in acute ...
612409 - Capillary filtration coefficient in the canine hindpaw at different levels of venous pr...
1656699 - Plasma angiotensin-converting enzyme activity and blood pressure during the first year ...
2996099 - The effects of volume loading during epidural analgesia.
2435669 - Iloprost, a stable prostacyclin analog, reduces intraocular pressure.
Publication Detail:
Type:  Journal Article; Review    
Journal Detail:
Title:  Critical care medicine     Volume:  34     ISSN:  0090-3493     ISO Abbreviation:  Crit. Care Med.     Publication Date:  2006 Aug 
Date Detail:
Created Date:  2006-08-02     Completed Date:  2006-08-31     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0355501     Medline TA:  Crit Care Med     Country:  United States    
Other Details:
Languages:  eng     Pagination:  2224-7     Citation Subset:  AIM; IM    
Affiliation:
McGill University Health Centre, Montreal, Quebec, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Atrial Function, Right / physiology
Cardiac Output / physiology
Central Venous Pressure / physiology*
Coronary Circulation / physiology
Humans
Monitoring, Physiologic / methods

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Pilot study on the effects of high cutoff hemofiltration on the need for norepinephrine in septic pa...
Next Document:  Tumor necrosis factor-alpha and interleukin-10 gene expression in peripheral blood mononuclear cells...