Catheter entrapment during balloon angioplasty in patient with in-stent restenosis: an unusual complication and its surgical management.
MedLine Citation:
PMID:  17338758     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Entrapment of coronary angioplasty hardware is one of the rare complications of percutaneous coronary artery interventions. We reported herein a case of 58-year-old man with an entrapped balloon catheter and guidewire within the right coronary artery during the application of a conventional balloon angioplasty for in-stent restenosis. Surgical removal of the entrapped balloon catheter and guidewire was performed successfully with a coronary artery bypass grafting to the affected vessel. The application of the balloon angioplasty for in-stent restenosis requires every caution against such type of complications.
Authors:
Ibrahim Goksin; Ahmet Baltalarli; Ender Semiz; Ercan Gurses; Mustafa Sacar; Vefa Ozcan; Hulya Sungurtekin
Related Documents :
2399838 - Assessment of risk of carotid occlusion with balloon matas testing and dynamic computed...
8888898 - An observation of the effects of paraffin paste on nasal epistaxis balloons.
7787278 - Recent developments in balloon valvuloplasty techniques.
7923688 - Inhibition of platelet deposition and lysis of intracoronary thrombus during balloon an...
3155548 - Biliary sclerosis in patients receiving hepatic arterial infusions of floxuridine.
3682418 - S1-receptor participation in serotonin-induced pulmonary edema in the dog.
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  Journal of cardiac surgery     Volume:  22     ISSN:  0886-0440     ISO Abbreviation:  J Card Surg     Publication Date:    2007 Mar-Apr
Date Detail:
Created Date:  2007-03-06     Completed Date:  2007-08-08     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8908809     Medline TA:  J Card Surg     Country:  United States    
Other Details:
Languages:  eng     Pagination:  160-2     Citation Subset:  IM    
Affiliation:
Department of Cardiovascular Surgery, Pamukkale University Faculty of Medicine, Heart Center, 20070 Kinikli/Denizli, Turkey. ibrahimgoksin@hotmail.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Angina, Unstable / therapy
Angioplasty, Transluminal, Percutaneous Coronary / adverse effects*,  instrumentation*
Coronary Angiography
Coronary Artery Bypass
Coronary Restenosis / etiology,  radiography,  surgery*,  therapy
Humans
Male
Middle Aged
Reoperation
Stents / adverse effects*