Catheter-based flow measurements in hemodialysis fistulas - Bench testing and clinical performance.
MedLine Citation:
PMID:  21725955     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Purpose: The purpose of this study was to perform bench and clinical testing of a catheter-based intravascular system capable of measuring blood flow in hemodialysis vascular accesses during endovascular procedures. Methods: We tested the Transonic ReoCath Flow Catheter System which uses the thermodilution method. A simulated vascular access model was constructed for the bench test. In total, 1960 measurements were conducted and the results were used to determine the accuracy and precision of the catheters, the effects of external factors (e.g., catheter placement, injection duration), and to test for systematic bias. In the clinical study, two interventional radiologists conducted a total of 250 measurements in 14 patients with arteriovenous fistulas to determine clinical precision and enable testing for bias between measurers.Results: Accuracy was excellent for both catheters with a high level of agreement between results from the ReoCath Flow Catheter System and the reference flowmeter. Clinical precision, expressed as the mean coefficient of variation, was 5.9% and 4.7% for the antegrade and retrograde catheters, respectively. Flow measurements were significantly affected by the distance between a stenosis and the tip of a retrograde catheter with the effect being proportional to the degree of stenosis. There was no systematic bias between measurers. Conclusions: The Reocath Flow Catheter System was found to be accurate and precise. Reliable results require careful attention to catheter placement. Blood flow measurements provide unique information on the hemodynamic status of a vascular access and have the potential to optimize results of interventions.
Authors:
Søren T Heerwagen; Lars Lönn; Torben V Schroeder; Søren D Ladefoged; Marc A Hansen
Related Documents :
17364215 - Importance and interpretation of fast-response airway hygrometry during ventilation of ...
21262115 - Auto-immune haemolytic anaemia concurrent with plasmodium vivax infection: a case report.
570035 - The diagnosis of zygosity in twins.
7369185 - Evaluation of a pneumatic-tube system for delivery of blood specimens to the blood bank.
17405365 - Mathematical model for the hemodynamic response to venous occlusion measured with near-...
3962605 - Morphometric evaluation of post-ischemic capillary perfusion in selectively vulnerable ...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-6-24
Journal Detail:
Title:  The journal of vascular access     Volume:  -     ISSN:  1724-6032     ISO Abbreviation:  -     Publication Date:  2011 Jun 
Date Detail:
Created Date:  2011-7-4     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  100940729     Medline TA:  J Vasc Access     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Interventional Radiology, Rigshospitalet, Copenhagen - Denmark.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Central Venous Access Port devices - A pictorial review of common complications from the interventio...
Next Document:  Randomized clinical trial comparing endovenous laser ablation, radiofrequency ablation, foam sclerot...