Document Detail

Cardiovascular Magnetic Resonance in Cardiac Sarcoidosis with MR Conditional Pacemaker in Situ.
Jump to Full Text
MedLine Citation:
PMID:  21539747     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
ABSTRACT: Cardiovascular implantable electronic devices represent important limitations to magnetic resonance imaging (MRI). Recently, MRI-conditional dual chamber pacemakers and leads have become available. We describe a case of a patient with neuro-sarcoidosis presenting with diplopia and hydrocephalus requiring an MRI-conditional programmable ventriculo-peritoneal shunt, who developed complete heart block. In view of the ongoing need for neuro-imaging, MRI-conditional dual chamber pacemaker and leads were implanted. Cardiac and brain MRI were requested to guide immunosupression. Overall the scans demonstrated stable neurological disease, but confirmed cardiac sarcoid, with oedema on T2 weighted images suggesting active disease and extensive sub-endocardial late gadolinium enhancement, including the basal septum. This case illustrates why sarcoid patients who develop bradyarrhythmias should ideally have an MRI-conditional pacing system.
Authors:
Giovanni Quarta; Diana R Holdright; Gordon T Plant; Allan Harkness; Derek Hausenloy; Harpreet Hyare; James C Moon
Related Documents :
21477757 - Diffusion tensor imaging for evaluation of the childhood brain and pediatric white matt...
12008817 - Sonography in primary hyperparathyroidism: review with emphasis on scanning technique.
1177047 - Improved diagnosis of "nondelineated" thyroid nodules by oblique scintillation scanning...
21442267 - The effect of age on arteriovenous malformations in children and young adults undergoin...
9184887 - Mapping visual field with positron emission tomography by mathematical modeling of the ...
2733247 - Long-standing hiccup in a patient with sarcoidosis.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-5-3
Journal Detail:
Title:  Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance     Volume:  13     ISSN:  1532-429X     ISO Abbreviation:  -     Publication Date:  2011 May 
Date Detail:
Created Date:  2011-5-4     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9815616     Medline TA:  J Cardiovasc Magn Reson     Country:  -    
Other Details:
Languages:  ENG     Pagination:  26     Citation Subset:  -    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): J Cardiovasc Magn Reson
ISSN: 1097-6647
ISSN: 1532-429X
Publisher: BioMed Central
Article Information
Download PDF
Copyright ©2011 Quarta et al; licensee BioMed Central Ltd.
open-access:
Received Day: 14 Month: 2 Year: 2011
Accepted Day: 3 Month: 5 Year: 2011
collection publication date: Year: 2011
Electronic publication date: Day: 3 Month: 5 Year: 2011
Volume: 13 Issue: 1
First Page: 26 Last Page: 26
ID: 3108926
Publisher Id: 1532-429X-13-26
PubMed Id: 21539747
DOI: 10.1186/1532-429X-13-26

Cardiovascular magnetic resonance in cardiac sarcoidosis with MR conditional pacemaker in situ
Giovanni Quarta12 Email: giovanni.quarta@yahoo.it
Diana R Holdright1 Email: diana.holdright@uclh.nhs.uk
Gordon T Plant3 Email: gordon.plant@uclh.nhs.uk
Allan Harkness4 Email: allan.harkness@colchesterhospital.nhs.uk
Derek Hausenloy1 Email: d.hausenloy@ucl.ac.uk
Harpreet Hyare56 Email: harpreet.hyare@nhs.net
James C Moon17 Email: james.moon@uclh.nhs.uk
1Department of Cardiology, The Heart Hospital, part of University College London Hospitals NHS Trust, 16-18 Westmoreland Street, London. W1G 8PH, UK
2Department of Cardiology, S. Andrea Hospital, University "La Sapienza", Rome, Italy
3National Hospital for Neurology and Neurosurgery Queen Square, University College London Hospitals NHS Trust London WC1N 3BG, UK
4Department of Cardiology, Colchester Hospital University NHS Foundation Trust, Colchester, UK
5Department of Imaging, University College London Hospitals NHS Trust, 250 Euston Road, London. NW1 2PG, UK
6MRC Prion Unit, Department of Neurodegenerative Diseases, UCL Institute of Neurology, Queen Square, London. WC1N 3BG, UK
7Department of Medicine, University College London, London, UK

Background

In the last decade, magnetic resonance imaging (MRI) has grown dramatically. At the same time, a growing number of patients receive cardiovascular implantable electronic devices (pacemaker, implantable-cardioverter defibrillators, bi-ventricular devices), a known contra-indication to MRI. It has been estimated that a patient with a cardiovascular electronic device has a 50-75% lifetime requirement for MRI, which would usually be denied [1]. A position paper from the European Heart Rhythm Association and the Working Group on Cardiovascular Magnetic Resonance of the European Society of Cardiology [1] and a scientific statement from the American Heart Association [2] on MRI in individuals with cardiovascular implantable electronic devices have been published. Recently, an MRI-conditional dual chamber pacemaker has become available and represents an important step forward to overcome one of the major limitations of MRI.


Case presentation

A 53 year old woman presented with fatigue in complete heart block. Transthoracic echocardiography was normal. Six years previously, neuro-sarcoidosis presenting with diplopia and hydrocephalus had been confirmed by meningeal biopsy, and an MRI-conditional programmable Ventriculo-Peritoneal shunt (PS Medical Strata® valve, Medtronic) had been inserted. In view of her ongoing need for neuro-imaging, MRI-conditional dual chamber pacemaker and leads (Advisa DR MRI™ SureScan™ with 5086 leads, Medtronic, Figure 1) were implanted. Subsequently, in September 2010, cardiac and brain MRI were requested to guide immunosupression. Following appropriate protocols for both MRI conditional devices, interleaved pre and post contrast cardiac, brain, and orbit MRI were performed in one session at 1.5T. Prior to scanning, the pacemaker was interrogated, lead integrity checked and device switched to DOO mode at 60 bpm at 5V@1ms (from 2V@0.4ms). Post scanning, all pacemaker parameters were unaffected, and normal operation was reprogrammed. Similarly, the programmable VP shunt, whose settings alter with scanning, was reset.

Brain MRI showed susceptibility artefact associated with the shunt (Figure 2), but otherwise stable intracranial disease with scattered white matter lesions and persistent dural enhancement. Cardiac MRI showed normal LV size and systolic function with no regional wall motion abnormalities. Metallic lead artefact was minimised by switching standard SSFP cine sequence (Figure 3 and additional file 1) to spoiled gradient echo - but was not considered necessary. T2-weighted images showed basal antero-septal oedema and there was extensive sub-epicardial, sometimes transmural, basal late gadolinium enhancement (Figure 4). Overall the scans demonstrated stable neurological disease, but confirmed cardiac sarcoid, with oedema suggesting active disease.


Conclusions

The advent of MRI-conditional devices overcomes an important limitation in disease management. Here, a multidisciplinary team approach and the use and management of two concurrent MR conditional devices [3] permitted ongoing, comprehensive assessment of multisystem sarcoidosis [4,5]. Ironically, cardiovascular MRI detected occult cardiac disease that suggests the possible future requirement for an implantable-cardioverter defibrillator. As yet, such devices are not MRI conditional. Fortunately, she has no other high risk features [6] and her device has not detected any ventricular arrhythmia. Our case illustrates why sarcoid patients who develop bradyarrhythmias should ideally have an MRI-conditional pacing system.


Consent

Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.


Conflict of interests

The authors declare that they have no competing interests.

No disclosures


Authors' contributions

GQ and JCM have made substantial contributions to conception and design of the case, have been involved in drafting the manuscript and revising it critically for important intellectual content and have given final approval of the version to be published.

DRH, GTP, AH, DH and HH have made substantial contributions to conception and design of the case, have been involved in revising the manuscript critically for important intellectual content and have given final approval of the version to be published.


Supplementary Material Additional file 1

Top: SSFP gradient echo cine (left) and spoiled gradient echo (right) cine four chamber views. SSFP images are more susceptible to artefacts from pacemaker leads, but image quality is good. Bottom: SSFP-GRE short axis views, showing no regional wall motion abnormalities.


Click here for additional data file (1532-429X-13-26-S1.AVI)


References
Roguin A,Schwitter J,Vahlhaus C,Lombardi M,Brugada J,Vardas P,Auricchio A,Priori S,Sommer T,Magnetic resonance imaging in individuals with cardiovascular implantable electronic devicesEuropaceYear: 2008103364610.1093/europace/eun02118308754
Levine GN,Gomes AS,Arai AE,Bluemke DA,Flamm SD,Kanal E,Manning WJ,Martin ET,Smith JM,Wilke N,Shellock FS,American Heart Association Committee on Diagnostic and Interventional Cardiac Catheterization; American Heart Association Council on Clinical Cardiology; American Heart Association Council on Cardiovascular Radiology and InterventionSafety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic ResonanceCirculationYear: 200711628789110.1161/CIRCULATIONAHA.107.18725618025533
Wilkoff BL,Bello D,Taborsky M,Vymazal J,Kanal E,Heuer H,Hecking K,Johnson WB,Young W,Ramza B,Akhtar N,Kuepper B,Hunold P,Luechinger R,Puererfellner H,Duru F,Gotte MJ,Sutton R,Sommer T,EnRhythm MRI SureScan Pacing System Study InvestigatorsMagnetic Resonance Imaging in Patients with a Pacemaker System Designed for the MR EnvironmentHeart RhythmYear: 20118657310.1016/j.hrthm.2010.10.00220933098
Iannuzzi MC,Rybicki BA,Teirstein AS,SarcoidosisN Engl J MedYear: 200735721536510.1056/NEJMra07171418032765
Patel MR,Cawley PJ,Heitner JF,Klem I,Parker MA,Jaroudi WA,Meine TJ,White JB,Elliott MD,Kim HW,Judd RM,Kim RJ,Detection of myocardial damage in patients with sarcoidosisCirculationYear: 200912019697710.1161/CIRCULATIONAHA.109.85135219884472
Epstein AE,DiMarco JP,Ellenbogen KA,Estes NA,Freedman RA,Gettes LS,Gillinov AM,Gregoratos G,Hammill SC,Hayes DL,Hlatky MA,Newby LK,Page RL,Schoenfeld MH,Silka MJ,Stevenson LW,Sweeney MO,Smith SC Jr,Jacobs AK,Adams CD,Anderson JL,Buller CE,Creager MA,Ettinger SM,Faxon DP,Halperin JL,Hiratzka LF,Hunt SA,Krumholz HM,Kushner FG,Lytle BW,Nishimura RA,Ornato JP,Page RL,Riegel B,Tarkington LG,Yancy CW,American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices); American Association for Thoracic Surgery; Society of Thoracic SurgeonsACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic SurgeonsCirculationYear: 2008117e35040818483207

Figures

[Figure ID: F1]
Figure 1 

Chest radiograph (left) and magnified image (right) of pacemaker. White arrows show the MRI-conditional marker on the header of the can (long arrow and schematic) and similar wavy line marker on the leads (short arrows).



[Figure ID: F2]
Figure 2 

Metallic artefact from the devices in the chest wall and skull.



[Figure ID: F3]
Figure 3 

SSFP cine 4 chamber view showing some susceptibility artefact from the pacemaker leads (white arrows).



[Figure ID: F4]
Figure 4 

Cardiac MRI with T2-weighted STIR images (left panel) showing oedema (arrow) and (middle and right panels) extensive patchy late gadolinium enhancement typical of sarcoid.



Article Categories:
  • Case Report


Previous Document:  Who is to blame? Perspectives of caregivers on barriers to accessing healthcare for the under-fives ...
Next Document:  Regulation of gene expression in human tendinopathy.