Document Detail


Cardiac output monitoring in newborns.
MedLine Citation:
PMID:  20171816     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
There is an increased interest in methods of objective cardiac output measurement in critically ill patients. Several techniques are available for measurement of cardiac output in children, although this remains very complex in newborns. Cardiac output monitoring could provide essential information to guide hemodynamic management. An overview is given of various methods of cardiac output monitoring with advantages and major limitations of each technology together with a short explanation of the basic principles.
Authors:
Willem-Pieter de Boode
Related Documents :
3395526 - Reproducibility of cardiac output measurement by cross sectional and doppler echocardio...
12476476 - Measuring cardiac output during dobutamine infusion after off-pump coronary artery bypa...
6409016 - Analysis of oral molsidomine effects on ventricular function and dimensions in the cons...
9187596 - Whole-body impedance cardiography in the measurement of cardiac output.
2627956 - Acute myocardial ischaemia and cardiogenic shock after percutaneous transluminal corona...
7302646 - Amyloid heart disease.
Publication Detail:
Type:  Journal Article     Date:  2010-02-19
Journal Detail:
Title:  Early human development     Volume:  86     ISSN:  1872-6232     ISO Abbreviation:  Early Hum. Dev.     Publication Date:  2010 Mar 
Date Detail:
Created Date:  2010-03-30     Completed Date:  2010-07-02     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7708381     Medline TA:  Early Hum Dev     Country:  Ireland    
Other Details:
Languages:  eng     Pagination:  143-8     Citation Subset:  IM    
Copyright Information:
Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Affiliation:
Radboud University Nijmegen Medical Centre, Department of Neonatology, Nijmegen, The Netherlands. W.deBoode@cukz.umcn.nl
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Cardiac Output / physiology*
Electric Impedance
Humans
Indicator Dilution Techniques
Infant, Newborn / physiology*
Monitoring, Physiologic / methods*
Practice Guidelines as Topic
Ultrasonography, Doppler

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Clinical monitoring of systemic hemodynamics in critically ill newborns.
Next Document:  The effect of whole body vibration exposure on muscle or bone morphology and function in older adult...