Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs.
MedLine Citation:
PMID:  22171359     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: /st>Cardiac output (CO) monitoring remains complex in newborns as most of the current technologies fail to accurately measure systemic blood flow in the presence of shunts. We validated CO measurements using transpulmonary ultrasound dilution (TPUD) in a neonatal lamb model with a left-to-right shunt. METHODS: /st>Regular arterial and central venous catheters were inserted into seven lambs (3.5-8.3 kg). A surgically constructed left-to-right aorto-pulmonary Gore-Tex(®) shunt was intermittently opened and closed, while CO was manipulated by creating haemorrhagic hypotension. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe positioned around the main pulmonary artery (COufp). RESULTS: /st>We performed 72 sessions of three paired CO measurements. The mean COufp was 1.00 litre min(-1) (range 0.47-1.75 litre min(-1)) and mean COtpud 1.05 litre min(-1) (range 0.54-1.87 litre min(-1)). With an open shunt, the mean Qp/Qs ratio was 1.8 (range 1.3-2.6). A comparison between COufp and COtpud showed a mean bias (sd) of 0.03 (0.09) and 0.07 (0.10) litre min(-1), respectively, for measurements with a closed and an open shunt. The percentage error was 18% and 20% for measurements with a closed and an open shunt. Polar plot analysis showed good trending ability for both closed and open shunt groups. CONCLUSIONS: /st>TPUD is a reliable technology to measure CO in the presence of a left-to-right shunt.
Authors:
S L Vrancken; W P de Boode; J C Hopman; S K Singh; K D Liem; A F van Heijst
Related Documents :
9220259 - Alien hand syndrome: influence of neglect on the clinical presentation of frontal and c...
945509 - Asymmetry of the lateral (sylvian) fissures in man.
9840089 - Left-sided gallbladder on the basis of a right-sided round ligament.
14764169 - Localization of accessory pathways by the electrocardiogram: which is the degree of acc...
22996589 - Dense accumulation of lipiodol emulsion in hepatocellular carcinoma nodule during selec...
10363879 - Echocardiographic and morphologic characteristics of left atrial myxoma and their relat...
16989669 - Clinical review: alternative vascular access techniques for continuous hemofiltration.
12866609 - Current concepts of mechanical cerebral protection during precutaneous carotid interven...
8311209 - The effects of entonox and epidural analgesia on arterial oxygen saturation of women in...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-12-14
Journal Detail:
Title:  British journal of anaesthesia     Volume:  -     ISSN:  1471-6771     ISO Abbreviation:  -     Publication Date:  2011 Dec 
Date Detail:
Created Date:  2011-12-15     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0372541     Medline TA:  Br J Anaesth     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Paediatrics (Neonatology).
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison w...
Next Document:  Variations in the gender composition of immigrant populations: how they matter.