Document Detail


Cardiac output measurement in patients with an implanted pacemaker.
MedLine Citation:
PMID:  18002106     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
In this paper we present a study of measuring the cardiac output at patients with implanted pacemakers. The cardiac output is measured with respect to the atrio-ventricular delay. We have scored the maximum relative cardiac output for each patient. For the measurement we have used a home made digital bioimpedance monitor for impedance cardiography. The result of 26 patients is presented in this study.
Authors:
Vlastimil Vondra; Josef Halamek; Ivo Viscor; Pavel Jurak; Miroslav Novak
Related Documents :
1541096 - Continuous measurement of cardiac output by the fick principle: clinical validation in ...
1609936 - Haemodynamic effects and uptake of enflurane in patients undergoing cardiac surgery: go...
2943016 - Continuous monitoring of cardiac output postoperatively using an implantable doppler pr...
20171816 - Cardiac output monitoring in newborns.
23489996 - Worse stroke outcome in atrial fibrillation is explained by more severe hypoperfusion, ...
20450906 - Cardioprotective effects of 44bu, a newly synthesized compound, in rat heart subjected ...
Publication Detail:
Type:  Clinical Trial; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference     Volume:  2007     ISSN:  1557-170X     ISO Abbreviation:  Conf Proc IEEE Eng Med Biol Soc     Publication Date:  2007  
Date Detail:
Created Date:  2007-11-16     Completed Date:  2008-03-14     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101243413     Medline TA:  Conf Proc IEEE Eng Med Biol Soc     Country:  United States    
Other Details:
Languages:  eng     Pagination:  916-8     Citation Subset:  IM    
Affiliation:
Institute of Scientific Instruments, Academy of Sciences of the Czech Republic, Kralovopolska 147, 612 64 Brno, Czech Republic. vond@isibrno.cz
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Cardiac Output*
Cardiac Pacing, Artificial / methods*
Cardiography, Impedance / methods*
Diagnosis, Computer-Assisted / methods*
Female
Heart Failure / diagnosis,  physiopathology*,  prevention & control*
Humans
Male
Reproducibility of Results
Sensitivity and Specificity
Therapy, Computer-Assisted / methods

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  New physiological model of serum creatine phosphokinase activity in acute myocardial infarction. Est...
Next Document:  Dynamic QT/RR coupling in patients with pacemakers.