Document Detail


Can a partial volume edge effect reduction algorithm improve the repeatability of subject-specific finite element models of femurs obtained from CT data?
MedLine Citation:
PMID:  22452517     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
The reliability of patient-specific finite element (FE) modelling is dependent on the ability to provide repeatable analyses. Differences of inter-operator generated grids can produce variability in strain and stress readings at a desired location, which are magnified at the surface of the model as a result of the partial volume edge effects (PVEEs). In this study, a new approach is introduced based on an in-house developed algorithm which adjusts the location of the model's surface nodes to a consistent predefined threshold Hounsfield unit value. Three cadaveric human femora specimens were CT scanned, and surface models were created after a semi-automatic segmentation by three different experienced operators. A FE analysis was conducted for each model, with and without applying the surface-adjustment algorithm (a total of 18 models), implementing identical boundary conditions. Maximum principal strain and stress and spatial coordinates were probed at six equivalent surface nodes from the six generated models for each of the three specimens at locations commonly utilised for experimental strain guage measurement validation. A Wilcoxon signed-ranks test was conducted to determine inter-operator variability and the impact of the PVEE-adjustment algorithm. The average inter-operator difference in stress values was significantly reduced after applying the adjustment algorithm (before: 3.32 ± 4.35 MPa, after: 1.47 ± 1.77 MPa, p = 0.025). Strain values were found to be less sensitive to inter-operative variability (p = 0.286). In summary, the new approach as presented in this study may provide a means to improve the repeatability of subject-specific FE models of bone obtained from CT data.
Authors:
Eran Peleg; Ryan Herblum; Maarten Beek; Leo Joskowicz; Meir Liebergall; Rami Mosheiff; Cari Whyne
Related Documents :
21287107 - Selecting the best unbalanced repeated measures model.
22575307 - Optimizing metabolic pathways by screening for feasible synthetic reactions.
24287097 - Molecular dating, evolutionary rates, and the age of the grasses.
12507337 - A method for evaluation of manual work using synchronised video recordings and physiolo...
23750227 - Spatial prediction of n2o emissions in pasture: a bayesian model averaging analysis.
23617317 - Pharmacophore assessment through 3-d qsar:evaluation of the predictive ability on new d...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-3-28
Journal Detail:
Title:  Computer methods in biomechanics and biomedical engineering     Volume:  -     ISSN:  1476-8259     ISO Abbreviation:  -     Publication Date:  2012 Mar 
Date Detail:
Created Date:  2012-3-28     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9802899     Medline TA:  Comput Methods Biomech Biomed Engin     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
a Computer Assisted Surgical Laboratory (CASL), Department of Biomedical Engineering , Hadassah University Medical Center , P.O.B.12000 , Jerusalem , Israel.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  SCORTEN and impaired renal function related to mortality of toxic epidermal necrolysis syndrome pati...
Next Document:  Discovery of the Novel Potent and Selective FLT3 Inhibitor 1-{5-[7-(3- Morpholinopropoxy)quinazolin-...