Document Detail


Can arterial stiffness parameters be measured in the sitting position?
MedLine Citation:
PMID:  20962783     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Despite the introduction of arterial stiffness measurements in the European recommendation, pulse wave velocity (PWV) and augmentation index (AI) are still not used routinely in clinical practice. It would be of advantage if such measurements were done in the sitting position as is done for blood pressure. The aim of this study was to evaluate whether there is a difference in stiffness parameters in sitting vs. supine position. Arterial stiffness was measured in 24 healthy volunteers and 20 patients with cardiovascular disease using three different devices: SphygmoCor (Atcor Medical, Sydney, Australia), Arteriograph (TensioMed, Budapest, Hungary) and Vascular Explorer (Enverdis, Jena, Germany). Three measurements were performed in supine position followed by three measurements in sitting position. Methods were compared using correlation and Bland-Altman analysis. There was a significant correlation between PWV in supine and sitting position (Arteriograph: P<0.0001, r=0.93; Vascular Explorer; P<0.0001, r=0.87). There were significant correlations between AI sitting and AI supine using Arteriograph (P<0.0001, r=0.97), Vascular Explorer (P<0.0001, r=0.98) and SphygmoCor (P<0.0001, r=0.96). When analyzed by Bland-Altman, PWV and AI measurements in supine vs. sitting showed good agreement. There was no significant difference in PWV obtained with the three different devices (Arteriograph 7.5±1.6 m s(-1), Vascular Explorer 7.3±0.9 m s(-1), SphygmoCor 7.0±1.8 m s(-1)). AI was significantly higher using the Arteriograph (17.6±15.0%) than Vascular Explorer and SphygmoCor (10.2±15.1% and 10.3±18.1%, respectively). The close agreement between sitting and supine measurements suggests that both PWV and AI can be reliably measured in the sitting position.
Authors:
Jens Nürnberger; Rene Michalski; Tobias R Türk; Anabelle Opazo Saez; Oliver Witzke; Andreas Kribben
Related Documents :
15333413 - A comparison of the failure times of pulse oximeters during blood pressure cuff-induced...
7061683 - Pulse pressure-ii. factors associated with follow-up values in three chicago epidemiolo...
12853833 - Risk of detrusor denervation in antireflux surgery demonstrated in a neurophysiological...
Publication Detail:
Type:  Journal Article     Date:  2010-10-21
Journal Detail:
Title:  Hypertension research : official journal of the Japanese Society of Hypertension     Volume:  34     ISSN:  1348-4214     ISO Abbreviation:  Hypertens. Res.     Publication Date:  2011 Feb 
Date Detail:
Created Date:  2011-02-07     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9307690     Medline TA:  Hypertens Res     Country:  England    
Other Details:
Languages:  eng     Pagination:  202-8     Citation Subset:  IM    
Affiliation:
Department of Nephrology and Dialysis, HELIOS Kliniken Schwerin, Wismarsche Straße, Schwerin, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Association of nighttime hypertension with central arterial stiffness and urinary albumin excretion ...
Next Document:  Should primary aldosteronism be diagnosed among normotensive subjects during general health check-up...