Abstract/OtherAbstract:
This work aims to provide a methodology to improve the analysis of color-M-Mode (CMM) echocardiograms, as used to assess cardiac function. Specifically, we presented a methodology for the combined analysis of multiple heartbeat cycles and improve the accuracy of intraventricular pressure difference (IVPD) calculation. CMM sweep speed and heartbeat variations impact the accuracy of IVPD calculation. Proper orthogonal decomposition (POD) is used to decompose and reconstruct a representative CMM scan from multiple heartbeats, with reduced noise and improved resolution. For three demonstration subjects, at least 9 beats were recorded at sweep speeds of 25, 50, 75, 100, and 150 mm/s. For all subjects, the beats from the 25 mm/s group resulted in low IVPD (median values: 1.93, 1.94 and 3.15 mmHg) compared to the 150 mm/s group (median values: 3.67, 3.98 and 5.18 mmHg). Reconstructed heartbeats for these subjects returned IVPD of 4.74, 3.23, and 5.14 mmHg. These results demonstrate the strong dependence of IVPD on the temporal resolution and that the proposed reconstruction method can return more accurate IVPDs for low resolution CMMs. This new method was applied to 5 clinical cohorts (3 normals, 1 restrictive, and 1 hypertrophied) and returned increased median IVPD from 2.93-4.41 mmHg for Normal 1, 2.14-3.30 mmHg for Normal 2, 1.84-3.64 mmHg for Normal 3, 2.28-3.00 mmHg for restrictive and 1.56-1.69 mmHg for hypertrophied. Our results show that beat-to-beat variations and temporal resolution affect the IVPD. Our new method rectifies low resolutions and beat-to-beat variability of the CMM data and allows for more accurate IVPD measurement independent of scanner acquisition settings and beat variations.
Authors:
Pavlos P Vlachos; Casandra L Niebel; Sreyashi Chakraborty; Min Pu; William C Little
Related Documents :
25227454 - Calculating intraventricular pressure difference using a multi-beat spatiotemporal reco...
25227064 - Technological solution for determining gait parameters using pressure sensors: a case s...
3279824 - Response of hypertensive rats to acute and chronic conditions of static exercise.
25418964 - Effect of medial opening wedge high tibial osteotomy on intraarticular knee and ankle c...
22259604 - Morning hypertension in treated hypertensives: baseline characteristics and clinical im...
8495554 - Central and peripheral vasopressin interact differently with sympathetic nervous system...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2014-9-17
Journal Detail:
Title:  Annals of biomedical engineering     Volume:  -     ISSN:  1573-9686     ISO Abbreviation:  Ann Biomed Eng     Publication Date:  2014 Sep 
Date Detail:
Created Date:  2014-9-17     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0361512     Medline TA:  Ann Biomed Eng     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Osteoblast Lineage Cells Can Discriminate Microscale Topographic Features on Titanium-Aluminum-Vanad...
Next Document:  Etiology and treatment of arterial ischemic stroke in children and young adults.