AIMS: This study introduces a non-invasive method based on computed tomography (CT) verification to ensure patients are accurately positioned before fractionated stereotactic radiotherapy. It enables quality control of mask positioning with reference to the CT images of the treatment plan. MATERIALS AND METHODS: A mask system, together with a dental impression moulded mouth bite, was used for patient immobilisation. In order to facilitate relevant image comparison, special alignment during CT localisation was discussed in the study. The accuracy of patient set-up was studied by assessing the isocentre position in relation to the patient's anatomical structure. The planning CT images were applied as a reference and the study was applied to 261 cranial applications. RESULTS: The results show that the mean and the maximum overall displacements at the isocentre were 0.7 and 2.5 mm, respectively. The mean and the maximum rotational displacement in the axial plane were 0.56 degrees and 2 degrees, respectively. The mean translational displacement and rotational displacement were close to zero when considering the direction of movement. CONCLUSIONS: The results indicate that the systematic error of the mask system and the verification method are minimal. Advantages of this technique include the simple set-up, three-dimensional quantification and short study time (10-15 min). It is therefore practical to implement on a routine basis. Investigation of the ability to relocate the mask is also recommended to justify the required safety margin between the clinical and planning target volumes.
Authors:
V Y W Wong; S Y Tung; T W Leung; K H S Ho
Related Documents :
21885729 - Optical differentiation between malignant and benign lymphadenopathy by greyscale textu...
21724119 - Impact of different window settings on colon polyp measurements with ct virtual colonos...
15895569 - Effects of x-ray and ct image enhancements on the robustness and accuracy of a rigid 3d...
22392019 - Postmortem ct investigation of skeletal and dental maturation of the fetuses and newbor...
20367339 - Precision of navigated stereotactic probe implantation into the brainstem.
21843269 - Novel three-dimensional imaging technique improves the accuracy of hepatic volumetric a...
11462309 - Intracranial vasculitis and multiple abscesses in a pregnant woman.
22591719 - Correlation between dynamic contrast-enhanced perfusion mri relative cerebral blood vol...
21885729 - Optical differentiation between malignant and benign lymphadenopathy by greyscale textu...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Clinical oncology (Royal College of Radiologists (Great Britain))     Volume:  15     ISSN:  0936-6555     ISO Abbreviation:  Clin Oncol (R Coll Radiol)     Publication Date:  2003 Aug 
Date Detail:
Created Date:  2003-08-19     Completed Date:  2003-11-25     Revised Date:  2008-03-10    
Medline Journal Info:
Nlm Unique ID:  9002902     Medline TA:  Clin Oncol (R Coll Radiol)     Country:  England    
Other Details:
Languages:  eng     Pagination:  280-7     Citation Subset:  IM    
Affiliation:
Department of Clinical Oncology, Tuen Mun Hospital, Hong Kong, People's Republic of China. Victy_Wong@hotmail.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Dose Fractionation
Humans
Masks*
Radiotherapy, Computer-Assisted / methods*
Tomography, X-Ray Computed / methods*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Radiotherapy patterns of practice: T1N0 glottic cancer in Ontario, Canada.
Next Document:  Metastatic hepatocellular carcinoma.