Broadband diffuse optical spectroscopy measurement of hemoglobin concentration during hypovolemia in rabbits.
MedLine Citation:
PMID:  16772673     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Serial blood draws for the assessment of trauma patients' hemoglobin (sHgb) and hematocrit (sHct) is standard practice. A device that would allow for continuous real-time, non-invasive monitoring of hemoglobin and tissue perfusion would potentially improve recognition, monitoring and resuscitation of blood loss. We developed a device utilizing diffuse optical spectroscopy (DOS) technology that simultaneously measures tissue scattering and near-infrared (NIR) absorption to obtain non-invasive measurements of oxy- (Hb-O(2)), deoxyhemoglobin (Hb-R) concentrations and tissue hemoglobin concentration (THC) in an animal model of hypovolemic shock induced by successive blood withdrawals. Intubated New Zealand White rabbits (N = 16) were hemorrhaged via a femoral arterial line every 20 min until a 20% blood loss (10-15 cc kg(-1)) was achieved to attain hypovolemia. A broadband DOS probe placed on the inner thigh was used to measure muscle concentrations of Hb-O(2) and Hb-R, during blood withdrawal. THC and tissue hemoglobin saturation (S(T)O(2)) were calculated from DOS [Hb-O(2)] and [Hb-R]. Broadband DOS-measured values were compared against traditional invasive measurements: systemic sHgb, arterial oxygen saturation (S(a)O(2)) and venous oxygen saturation (S(v)O(2)) drawn from arterial and central venous blood. DOS and traditional invasive measurements versus blood loss were closely correlated (r(2) = 0.96) showing a decline with removal of blood. S(T)O(2) and [Hb-O(2)] followed similar trends with hemorrhage, while [Hb-R] remained relatively constant. These measurements may be limited to some extent by the inability to distinguish between hemoglobin and myoglobin contributions to DOS signals in tissue at this time. Broadband DOS provides a potential platform for reliable non-invasive measurements of tissue oxygenated and deoxygenated hemoglobin and may accurately reflect the degree of systemic hypovolemia and compromised tissue perfusion.
Authors:
Jangwoen Lee; D J Saltzman; A E Cerussi; D V Gelfand; J Milliken; T Waddington; B J Tromberg; M Brenner
Related Documents :
17276113 - Hemoglobin-oxygen-affinity and acid-base properties of blood from the fossorial mole-ra...
21476423 - Alexis carrel: innovator extraordinaire.
21952513 - Oxygen sensing in retinal health and disease.
Publication Detail:
Type:  Evaluation Studies; Journal Article; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, Non-P.H.S.     Date:  2006-06-13
Journal Detail:
Title:  Physiological measurement     Volume:  27     ISSN:  0967-3334     ISO Abbreviation:  Physiol Meas     Publication Date:  2006 Aug 
Date Detail:
Created Date:  2006-06-14     Completed Date:  2006-10-05     Revised Date:  2008-11-21    
Medline Journal Info:
Nlm Unique ID:  9306921     Medline TA:  Physiol Meas     Country:  England    
Other Details:
Languages:  eng     Pagination:  757-67     Citation Subset:  IM    
Affiliation:
Beckman Laser Institute, University of California, Irvine, CA 92612, USA. jangwl@uci.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Animals
Hemoglobins / analysis*
Hypovolemia / diagnosis*
Male
Optics and Photonics
Rabbits
Reproducibility of Results
Spectrum Analysis / methods*
Chemical
Reg. No./Substance:
0/Hemoglobins

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Carmeli's S index assesses motion and muscle artefact reduction in rowers' electrocardiograms.
Next Document:  Capillary electrophoretic determination of self-dimerization constants of aromatic carboxylate and s...