Document Detail


Blood pressure measurement using finger cuff.
MedLine Citation:
PMID:  17280997     Owner:  NLM     Status:  PubMed-not-MEDLINE    
Abstract/OtherAbstract:
Many research groups have studied blood pressure measurement in finger artery because of its convenience. But, low accuracy prohibits many hypertension patients from using this device. So, we suggest measurement algorithm that measure systolic and diastolic blood pressure in finger artery. And we also develop calibration method that decreases the error from difference of finger circumference by subjects. We apply our methods for 90 subjects (age form 20 to 49, 55 male, 35 female) to test feasibility of our method by AAMI SP10 standard. The mean difference of our system is ±4.7mmHg for systolic pressure, ±4.2mmHg for systolic pressure. It proved that the feasibility of our method is clinically acceptable.(under ±5mmHg).
Authors:
J Lee; E Choi; H Jeong; K Kim; J Park
Related Documents :
11518837 - Rapid oscillometric blood pressure measurement compared to conventional oscillometric m...
15558917 - Brachial blood pressure monitoring versus ankle monitoring during colonoscopy.
6703297 - An assessment of the dinamap 845.
9072397 - Proper measurement of blood pressure and heart rate in shrsp and wky by an indirect vol...
1323337 - Atrial natriuretic peptide and urinary cyclic guanosine monophosphate in patients with ...
4045037 - Doppler echocardiographic estimation of systolic pulmonary artery pressure in pediatric...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference     Volume:  4     ISSN:  1557-170X     ISO Abbreviation:  Conf Proc IEEE Eng Med Biol Soc     Publication Date:  2005  
Date Detail:
Created Date:  2007-02-06     Completed Date:  2012-10-02     Revised Date:  2014-08-21    
Medline Journal Info:
Nlm Unique ID:  101243413     Medline TA:  Conf Proc IEEE Eng Med Biol Soc     Country:  United States    
Other Details:
Languages:  eng     Pagination:  3575-7     Citation Subset:  -    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Active motion artifact reduction for wearable sensors using laguerre expansion and signal separation...
Next Document:  A Preliminary Study for Unconstrained Pulse Arrival Time (PAT) Measurement on a Chair.