Biventricular Defibrillator Patients Have Higher Complication Rates after Revision of Recalled Leads.
MedLine Citation:
PMID:  22519559     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Background: Since the 2009 revised advisory statement regarding Sprint Fidelis® Defibrillator Lead failure rates (Medtronic Inc., Minneapolis, MN, USA), there has been a significant increase in revision of these leads. We sought to establish the frequency of major procedural complications and determine what patient characteristics were associated with these outcomes. Methods: We retrospectively reviewed the charts of 621 patients with Fidelis® leads being followed in the University of Pittsburgh Medical Center through January 1, 2010. The population was then examined for rates of lead malfunction, revision, and complication. Results: The average time from implantation of Fidelis® lead to endpoint was 32 ± 16 months. Overall lead survival rates were 89% at 41 months and were lower in biventricular implantable cardioverter defibrillator (BiVICD) as compared to standard implantable cardioverter defibrillator patients (log rank P = 0.053). Prophylactic revisions increased dramatically during 2009 (9.4% vs 1.4%, P < 0.001). Among the 131 patients who underwent revision during the entire time of follow-up, 11 patients had postoperative complications (8.5%). The only significant variable found between patients who did and did not have complications was the presence of a BiVICD (81.8 vs 48.7%, P = 0.036). Of the 40 total patients who underwent lead extraction, all three complications occurred in patients with BiVICDs. Conclusion: The number of prophylactic Fidelis® lead revisions has increased dramatically since 2008, and procedure-related complications have been higher than anticipated. Major procedural complication rates are greater among patients with BiVICDs. Overall, lead extraction does not appear to increase procedural risk as compared to abandonment. (PACE 2012;1-7).
Authors:
Genevieve E Brumberg; Bahaa Kaseer; Hemal Shah; Samir Saba; Sandeep Jain
Related Documents :
22826619 - Quality audit of colonoscopy reports amongst patients screened or surveilled for colore...
23231359 - Vascular and pulmonary embolisms following percutaneous vertebroplasty.
22890529 - The presence of fungal floras in sinuses in chronic sinusitis patients with polyps.
22580679 - Surgical treatment of pain in patients with chronic pancreatitis.
24122679 - The evolution of surgical procedures in the management of duodenal and gastric ulcers.
23120559 - Middle turbinate osteoma.
6110099 - Is preoperative localisation of insulinomas necessary?
9155109 - Mobile surgical teams of croatian special police forces: analysis of casualties during ...
1214689 - The influence of seat belt wearing on the incidence of severe head injury.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-4-22
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  -     ISSN:  1540-8159     ISO Abbreviation:  -     Publication Date:  2012 Apr 
Date Detail:
Created Date:  2012-4-23     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.
Affiliation:
University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Vasectomy reversal using a microsurgical three-layer technique: one surgeon's experience over 18?yea...
Next Document:  Comparative proteomic analysis of primary Schwann cells and a spontaneously immortalized Schwann cel...