Document Detail


Biomechanical evaluation of different abduction splints for the treatment of congenital hip dysplasia.
MedLine Citation:
PMID:  22781789     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: Abduction splints for the treatment of hip dysplasia normally operate on curbing the legs at the hip flexion and abduction. The forces are absorbed in different designs of shoulder straps and thus diverted to the shoulder and the spine. The present study is the first comparing these undesired forces of two spread orthoses and subsequently the transmitted forces to the infant's spine. METHODS: Between March 2009 and October 2009 the hips of 290 infants were investigated by ultrasound within the first 3days after birth. Thereof 20 infants with a hip dysplasia Graf type IIc, D or IIIa met our inclusion criteria and were investigated with a Tübinger and a Superior abduction splint. Biomechanical evaluation was performed by using a high-sensitive strain gauge sensor applied to the infant's orthoses between pelvic harness and shoulder straps. FINDINGS: The transmitted forces to the infant's shoulders correlated significantly with their body mass (P<0.05). Maximal forces on the shoulder of the infants and subsequently transmitted forces on the spine were significantly higher (P<0.05) with the Tübinger splint (range 7.6N to 32.3N; arithmetic mean M: 13.7N) in comparison to the Superior orthosis (range 0.0N to 3.5N; M: 0.7N). INTERPRETATION: The Superior orthosis works with primary load transmission to the pelvic bone. Using the Tübinger splint the shoulders of the newborn infants are loaded with a maximum of 93.9% of their body mass. This may influence the development of the growing infant's spine.
Authors:
Peter C Kreuz; Susanne Fröhlich; Tobias Lindner; Dirk Olbertz; Rainer Bader; Wolfram Mittelmeier
Related Documents :
19824049 - Use of intrapulmonary percussive ventilation (ipv) in the management of pulmonary compl...
12665999 - Distribution of lung ventilation in spontaneously breathing neonates lying in different...
23073749 - Maternal education, birth weight, and infant mortality in the united states.
25141039 - Anthropometry from birth to 24 months among offspring of women with gestational diabete...
23158509 - Donor human milk versus mother’s own milk in preterm vlbwis: a case control study.
24324639 - Long-term impact of preterm birth on exercise capacity in healthy young men: a national...
6211289 - Health visitor support for families with down's syndrome infants.
8936689 - Pointing and social awareness: declaring and requesting in the second year.
11236719 - Host defense benefits of breastfeeding for the infant. effect of breastfeeding duration...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-7-9
Journal Detail:
Title:  Clinical biomechanics (Bristol, Avon)     Volume:  -     ISSN:  1879-1271     ISO Abbreviation:  -     Publication Date:  2012 Jul 
Date Detail:
Created Date:  2012-7-11     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611877     Medline TA:  Clin Biomech (Bristol, Avon)     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2012 Elsevier Ltd. All rights reserved.
Affiliation:
Department of Orthopaedics, University Medical Center of Rostock, Doberaner Str. 142, 18057 Rostock, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Hot flushes and night sweats differ in associations with cardiovascular markers in healthy early pos...
Next Document:  [The impact of HLA high resolution typing mismatching of donor-recipient pairs on outcome of unrelat...