Biomechanical evaluation of different abduction splints for the treatment of congenital hip dysplasia.
MedLine Citation:
PMID:  22781789     Owner:  NLM     Status:  Publisher    
BACKGROUND: Abduction splints for the treatment of hip dysplasia normally operate on curbing the legs at the hip flexion and abduction. The forces are absorbed in different designs of shoulder straps and thus diverted to the shoulder and the spine. The present study is the first comparing these undesired forces of two spread orthoses and subsequently the transmitted forces to the infant's spine. METHODS: Between March 2009 and October 2009 the hips of 290 infants were investigated by ultrasound within the first 3days after birth. Thereof 20 infants with a hip dysplasia Graf type IIc, D or IIIa met our inclusion criteria and were investigated with a Tübinger and a Superior abduction splint. Biomechanical evaluation was performed by using a high-sensitive strain gauge sensor applied to the infant's orthoses between pelvic harness and shoulder straps. FINDINGS: The transmitted forces to the infant's shoulders correlated significantly with their body mass (P<0.05). Maximal forces on the shoulder of the infants and subsequently transmitted forces on the spine were significantly higher (P<0.05) with the Tübinger splint (range 7.6N to 32.3N; arithmetic mean M: 13.7N) in comparison to the Superior orthosis (range 0.0N to 3.5N; M: 0.7N). INTERPRETATION: The Superior orthosis works with primary load transmission to the pelvic bone. Using the Tübinger splint the shoulders of the newborn infants are loaded with a maximum of 93.9% of their body mass. This may influence the development of the growing infant's spine.
Peter C Kreuz; Susanne Fröhlich; Tobias Lindner; Dirk Olbertz; Rainer Bader; Wolfram Mittelmeier
Related Documents :
24997649 - Congenital heart disease in low-birth-weight infants: effects of small for gestational ...
23283659 - Change in weight-for-length status during the first three months: relationships to birt...
16238539 - Effects of open vs. closed system endotracheal suctioning on cerebral blood flow veloci...
25128999 - A mathematical algorithm for detection of late-onset sepsis in very-low birth weight in...
3558939 - High-frequency ventilation (hfv) in hyaline membrane disease--a preliminary report.
23293879 - Leak around endotracheal tubes in ventilated newborns: an observational study.
18576529 - Kinetics of ethanol production during the reactor feeding phase in constant feb-batch f...
15937579 - Variations in early and intermediate neonatal outcomes for inborn infants admitted to a...
9386659 - Rapid estimation of insertional length of endotracheal intubation in newborn infants.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-7-9
Journal Detail:
Title:  Clinical biomechanics (Bristol, Avon)     Volume:  -     ISSN:  1879-1271     ISO Abbreviation:  -     Publication Date:  2012 Jul 
Date Detail:
Created Date:  2012-7-11     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611877     Medline TA:  Clin Biomech (Bristol, Avon)     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2012 Elsevier Ltd. All rights reserved.
Department of Orthopaedics, University Medical Center of Rostock, Doberaner Str. 142, 18057 Rostock, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Previous Document:  Hot flushes and night sweats differ in associations with cardiovascular markers in healthy early pos...
Next Document:  [The impact of HLA high resolution typing mismatching of donor-recipient pairs on outcome of unrelat...