Document Detail


Bile duct stenting: a comparison of the One-Action Stent introduction system with the conventional delivery system.
MedLine Citation:
PMID:  8781794     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND AND STUDY AIMS: A "One-Action Stent Insertion System" (OASIS) for use with biliary stents has been produced, which is said to be easier to use than conventional insertion systems. The aim of this study was to assess whether there was any measurable difference in the technique in a comparison between the two methods. PATIENTS AND METHODS: A prospective study was carried out. Twenty consecutive patients requiring stents for biliary obstructing lesions were randomly allocated to have the stent inserted either using the OASIS system or the conventional system. All the sent insertions were performed by two experienced endoscopists. The actual time of the insertion procedure and the screening time were recorded. RESULTS: Patients' tolerance for the procedure was similar in the two groups. In nine out of ten OASIS stent insertions, the endoscopist considered the procedure to be easy, compared with five out of ten conventional stent placements. Both techniques resulted in satisfactory positioning of the stent in nine out of ten patients. Although there was no statistically significant difference in the screening times for the two methods (p = 0.16), the actual time taken using the conventional method was significantly longer than with the OASIS method (p < 0.001). CONCLUSION: The One-Action Stent Insertion Set (OASIS) allows easier insertion of biliary stents. The system decreases the number of exchanges that need to be undertaken, precluding inadvertent wire displacement and the need to reinitiate cannulation and guide wire insertion. The actual time required for insertion is significantly less using this method, and this may also reduce the radiation exposure.
Authors:
B W Lawrie; S Pugh; R Watura
Related Documents :
15849734 - Multislice ct to evaluate coronary stent patency: a case report.
10604884 - Optimizing the percutaneous interventional outcomes for patients with diabetes mellitus...
8808064 - Multicenter clinical experience with the development of a novel short coronary stent an...
19056134 - Long-term outcome after drug eluting stenting in patients with st-segment elevation myo...
18318924 - The teleguard trial of additional telemedicine care in cad patients. 1 utilization of t...
2768714 - Myocardial perfusion imaging by contrast echocardiography with use of intracoronary son...
Publication Detail:
Type:  Clinical Trial; Journal Article; Randomized Controlled Trial    
Journal Detail:
Title:  Endoscopy     Volume:  28     ISSN:  0013-726X     ISO Abbreviation:  Endoscopy     Publication Date:  1996 Mar 
Date Detail:
Created Date:  1996-11-18     Completed Date:  1996-11-18     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  0215166     Medline TA:  Endoscopy     Country:  GERMANY    
Other Details:
Languages:  eng     Pagination:  299-301     Citation Subset:  IM    
Affiliation:
Dept. of Diagnostic Radiology, University Hospital of Wales, Cardiff, United Kingdom.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Aged, 80 and over
Cholangiopancreatography, Endoscopic Retrograde / instrumentation*
Cholestasis / radiography,  therapy*
Equipment Design
Female
Humans
Male
Middle Aged
Stents*
Treatment Outcome

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine